The detectable warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured...
Search Results "Measuring Instrument"
-
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191
-
11B-703.2.5 Character height
Character height measured vertically from the baseline of the character shall be 5/8 inch (15.9 mm) minimum and 2 inches (51 mm) maximum based on the height of the uppercase letter “I”....
- Access-Able Designs Portable Clamp-On Tub Seat SH-426
- Bobrick Recessed Toilet Tissue Dispenser B-6677
- Bobrick Recessed Toilet Tissue Dispenser B-667
- Access-Able Designs Shower Transfer Bench SH-400-2SDL
-
11B-603.6 Guest room toilet and bathing rooms
that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
Cross Slope
Measurements, absent live loads, are to be made from a static condition (i.e., absence of movement that results from wind, waves, etc.)....
-
804.2 Clearance
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
T505.3 Location of Operable Parts
Operable parts shall be located adjacent to the toe end of the clear space or shall be located no more than 10 inches (255 mm) measured from the centerline of the long dimension of the clear...
-
Treads & Risers
[ADA Stds. 4.9] Yes __ No __ N/A __ Comments: ___________________________________________ ...are all stair treads the same depth (at least 11" deep), measured riser to riser, to prevent...
-
Running Slope
In other words, the slope is the difference in elevation from the beginning to the end of a part of a trail, outdoor recreation access route, or beach access route, measured in the direction...
-
Door Closers [4.13.10]
requires that the sweep period of the closer be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 inches from the latch, measured...
-
§ 38.153(c)(1)
(1) Doors shall have a minimum clear width when open of 30 inches (760 mm), measured from the lowest step to a height of at least 48 inches (1220 mm), from which point they may taper to...
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25 inches....
-
Summary
The data are based on findings from the Anthropometry of Wheeled Mobility (AWM) Project, and comprises of detailed static measurements collected from 500 users of manual wheelchairs, power...
-
10.3.1(9)
(9) In stations covered by this section, rail-to-platform height in new stations shall be coordinated with the floor height of new vehicles so that the vertical difference, measured when...
-
Accessible Pathway & Corridor: Minimum Clear Floor Space Required for 360-degree Turn
Findings from the Anthropometry of Wheeled Mobility Study indicate that a square space of at least 160 x 160 cm (63 in.) was required for 50% of the manual wheelchair users measured in this...
-
Accessible Pathway & Corridor: Minimum Clear Width Required for 90-degree Turn
Findings from the Anthropometry of Wheeled Mobility Study indicate that a width of at least 85 cm (33 in.) was required for 50% of the manual and power wheelchair users measured in this...
-
Clearance in Base (M301.4.1 and M302.4.1)
M301.4.1 and M302.4.1 would require the clearance in the base to be 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge...
-
11B-903.4 Back support
Back support shall be 2½ inches (64 mm) maximum from the rear edge of the seat measured horizontally. [2010 ADAS] 903.4 Back Support....