Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
Search Results "Fixed Equipment"
Commonly Searched Documents
-
M303.3.2 Beveled
-
Typical Transfer Techniques: Staff Assistance and Patient Lifts
The provider should ask the patient if he or she needs assistance, and if so, what is the best way to help and what extra equipment, if any, is needed....
-
T215 Communication Features
The Access Board received a substantial number of comments relating to the issue of whether large transit agencies should be required to equip their large fixed route buses with automated...
-
6. Minimum (Low) Height Standard for Transfer Surfaces
Minimum (Low) Height Standard for Transfer Surfaces As indicated in Section 5.1.1, the MDE Advisory Committee recommends that equipment with transfer surfaces be height adjustable in...
- Living Earth Crafts Cloud 9 Cuvee Spa Treatment Table
- Living Earth Crafts Cloud 9 Spa Treatment Table
-
Permitted Means of Pool Access
Permitted Means of Pool Access Pool Type Sloped Entry Lift Transfer Walls Transfer Systems Stairs Swimming (less than 300...
- Design Guidelines for the Visual Environment
- Midmark 625 Barrier-Free® Power Examination Table
- Midmark 623 Barrier-Free® Power Examination Table
- Midmark Ritter 222 Barrier-Free® Power Examination Table
- Midmark Ritter 223 Barrier-Free® Power Examination Table
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section...
-
226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with 902. In...
-
226.1 General
226.1 General. Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall...
-
B. Ticket Policies and Pricing:
As more specifically described in paragraphs 25 through 29 of this Settlement Agreement, Olympia shall ensure that its ticketing and pricing policies, practices, and procedures...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section...
-
11B-226.1 General
Where dining surfaces are provided for the consumption of food or drink, at least 5 percent of the seating spaces and standing spaces at the dining surfaces shall comply with Section...
-
Controls and Equipment
Controls and Equipment Access requirements apply to fixed controls and operating mechanisms intended for independent use by patients....
-
(1) Adjustability: Minimum High Transfer Height
In the preamble to the MDE NPRM, the Access Board sought comment in question 14 on whether the final rule should require an adjustable height range of 17 inches to 25 inches; whether equipment...
-
5. Edge Protection
The Access Board sought public input with question 30 in the MDE NPRM preamble, on whether there is diagnostic equipment with wheelchair spaces on raised platforms that does not provide...
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be...
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12. EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches...