Suggestion: Install a portable ramp with edge protection and handrails as shown in the figure or relocate the accessible voting to another area that is on an accessible route....
Search Results "Curb Ramp Top Landing"
Commonly Searched Documents
-
Temporary Solutions for Election Day
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
The vertical clearance at doorways with lifts, ramps or bridgeplates shall comply with T502.2....
-
1.2.7
1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope....
-
WILLITS, et al v. CITY OF LOS ANGELES - Settlement Terms
Willits v. City of Los Angeles Term Sheet as of March 30, 2015
-
WILLITS, et al v. CITY OF LOS ANGELES - Settlement Agreement and Release of Claims
UNITED STATES DISTRICT COURT CENTRAL DISTRICT OF CALIFORNIA CASE NO. CV 10-5782 CBM (RZx) SETTLEMENT AGREEMENT AND RELEASE OF CLAIMS MARK WILLITS, JUDY GRIFFIN,...
-
11B-250 Circulation paths
[See subsections ...]
-
4.8.5(4)
(4) Gripping surfaces shall be continuous.
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings.
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
11B-505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
B5. Curb Ramp
Is a curb ramp provided between the vehicle pull up area and the access aisle (see figure above) or the access aisle and the accessible route (see figure on page 9) to the accessible entrance...
-
§ 38.95(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches by 26 inches, with...
-
Play Components: ADA Standard Section 1008.4
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....
-
5.8.1.2.1 Ramped Entry Slope Recommendations
5.8.1.2.1 Ramped Entry Slope Recommendations The Committee recommends that raised platforms have a ramp with slopes that do not exceed the following: At 0 to 1½ inches, the slope...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2½ inches (64 mm) minimum measured...
-
11B-407.2.2.1 Visible and audible signals
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call and the car’s direction of travel. Where in-car signals are...
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2 1/2 inches (64 mm) minimum measured...
-
407.2.2.2 Visible Signals
407.2.2.2 Visible Signals. Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground. The visible signal elements shall be 2½ inches...