., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (101.6 mm)....
Search Results "Curb Ramp Top Landing"
Commonly Searched Documents
-
1132A.4, Item 3
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
1.2.6
1.2.6 When local variations (flatness) in running slope of ramps are measured according to 1.1.13 at least 80% (rounded to the nearest whole number) of the measurements should not exceed...
-
§27.75 Federal Highway Administration—highways.
[44 FR 31468, May 31, 1979, as amended by Amdt. 27-3, 51 FR 19017, May 23, 1986. Redesignated at 56 FR 45621, Sept. 6, 1991, as amended at 79 FR 21405, Apr. 16, 2014]
-
Maximum Slope at Ground Level
Maximum Slope at Ground Level The maximum allowable slope for a ground-level accessible route is 1:16. Berms are sometimes used to provide access to elevated play areas. A...
-
1132A.4, Item 3
., concrete, brick, flagstone) may have a maximum change in height from the interior landing of 4 inches (101.6 mm)....
-
T404.3 Ramps and Bridgeplates
platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger load with the vehicle at rest, non-rail vehicles shall provide ramps...
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
1.1.4
1.1.4 A maximum overall design running slope for exterior accessible ramps of 7.5% (1:13.3 or 1:13) is recommended....
-
Recreational Boating Facilities: ADA Standard Section 206.2.10
Section 206.2.10 covers scoping requirements in the most current ADA Standards for accessible routes to recreational boating facilities
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an area...
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope....
-
11B-206.2.10 Recreational boating facilities
Boat slips required to comply with Section 11B-235.2 and boarding piers at boat launch ramps required to comply with Section 11B-235.3 shall be on an accessible route....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum....
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum....
-
§ 38.83(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches, with a safety factor...
- How to Measure Ramp Handrail Extensions
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on both sides....
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side....
-
T205.1 General
Non-rail vehicles shall provide illumination complying with T503 at ramps, bridgeplates, doorways, and boarding and alighting areas....
-
Polling places that cannot be remediated with temporary measures:
Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2)....
-
Handrails [§405.8, §505]
Handrails [§405.8, §505] Handrails are required on both sides of ramps with a rise greater than 6”....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground. The visible signal elements shall be a minimum 2½ inches (64 mm) high by 2½...
-
11B-411.1.2 Car designations
SECTION TITLE NOTES 11B-411.1.2 Car designations. Clarifies requirements that each...