Clear floor space should be centered at lavatories. This clear floor space, which can overlap space required at water closets, must extend 17 to 19 inches below the lavatory....
Search Results "Clear"
-
Single-User Toilet Rooms: Side Transfer Space
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....
-
902.4.1 Clear Floor or Ground Space
A clear floor space complying with 305 positioned for forward approach shall be provided....
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
A4.23.3 Clear Floor Space
Figure A7 shows two possible configurations of a toilet room with a roll-in shower. The specific shower shown is designed to fit exactly within the dimensions of a standard bathtub....
- Pilot Rock Smoker's Cease Fire Ash Receptacle
-
1013.2.2 Surface
The surface of the clear ground space shall be firm and stable. The surface shall allow use of tent stakes and other tent securement devices....
-
1013.2.2 Surface
The surface of the clear ground space shall be firm and stable. The surface shall allow use of tent stakes and other tent securement devices....
-
Lavatories Adjacent to Partitions
Per 11B-606.2, we know that a clear space positioned for a forward approach is required (with exceptions), with proper knee and toe clearance. ...
-
11B-406.5.3 Landings
The landing clear length shall be 48 inches (1219 mm) minimum....
-
Doorways
Comment. In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to be at least 32 inches wide (224.1.2). This specification stems from the...
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance....
-
G1
G1. Is there an accessible route, at least 36 inches wide, that connects each sleeping area with other shelter activity areas? Yes No Note: it may narrow to 32 inches...
-
B) Accessible Route
When a walk, pathway, or pedestrian route is necessary to provide public access to a program, service, or activity, an accessible route must be provided. An accessible route is an...
-
1130A.2 Width
1130A.2 Width. The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide.
-
Tread Width
The visible trail surface measured perpendicular to the direction of travel.
-
C1-3. Accessible Route Width
C1-3. Is the accessible route at least 36 inches wide? If No, the accessible route may narrow to 32 inches wide for up to 2 feet in length. Yes _____ No _____
-
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters or Other Mobility Aids
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters or Other Mobility Aids There must be at least one exterior accessible route that connects accessible passenger...
-
4.21.2 Size and Clearances
4.21.2 Size and Clearances. Minimum guidelines for roll-in shower stalls are based on residential size fixtures (30" x 60" minimum or the space used by a standard residential...
-
Passing Space [§403.5.3]
Passing Space [§403.5.3] Passing space is required every 200 feet and must be provided as a 60” by 60” minimum space or as T-shaped space where each stem is at least 48”...
-
1130A.2 Width
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide.
-
11B-608.2.2.1 Clearance
11B-608.2.2.1 Clearance. A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010...
-
1130A.2 Width
The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide.