3. Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components. Exception: Two 15-inch (381 mm) wide minimum...
Search Results "Residential Amenity Center"
-
1133A.4, Item 3
-
1133A.7.1 Plumbing protection
Water supply and drain pipes under kitchen sinks shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under kitchen sinks.
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
[F] 907.5.2.3.2 Groups R-1 and R-2.1. Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification...
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30...
-
1133A.7.1 Plumbing protection
Water supply and drain pipes under kitchen sinks shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under kitchen sinks.
-
1010.1.7 Thresholds
Thresholds at doorways shall not exceed ¾ inch (19.1 mm) in height above the finished floor or landing for sliding doors serving dwelling units or ½ inch (12.7 mm) above the finished...
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
208 Parking Spaces
Exception is new 208.2.3 Residential Facilities. Parking spaces provided to serve residential facilities shall comply with 208.2.3....
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
Emergency Travel Safety Tips for Overnight Stays
Grant to North Carolina Emergency Management from The North Carolina Council on Developmental Disabilities Grant to North Carolina Emergency Management The Mid-Atlantic ADA Center...
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 18 inches (457 mm) minimum from the water closet centerline where...
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow...
- Marx|Okubo Associates, Inc., Accessibility Group (ADA and FFHA)
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-804.3 Kitchen work surface
In residential dwelling units required to comply with Section 11B-809, at least one 30 inches (762 mm) wide minimum section of counter shall provide a kitchen work surface that complies...
-
206.2.3 Multi-Story Buildings (Exception 4), F206.2.3 Multi-Story Buildings (Exception 4)
In facilities with residential dwelling units, an accessible route shall not be required to connect stories where residential dwelling units with mobility features required to comply with...
-
I. BACKGROUND
Defendant owns and operates more than 550 convenience stores and gas stations, and truck stop and travel center facilities, under the QuikTrip brand, located in at least nine states, including...
-
§ 36.401(d) Elevator exemption.
(d) Elevator exemption.