When in use, the touch surface of TTY keypads shall be 34 inches (864 mm) minimum above the finish floor....
Search Results "Finished Grade"
-
11B-704.4.1 Height
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
502.6 Identification
Signs shall be 60 inches (1525 mm) minimum above the finish floor or ground surface measured to the bottom of the sign....
-
7.4.11.2 Sign Contents
trail and related facilities), the location of specific trail features and obstacles that do not comply with the technical provisions in 7.4 should be identified and a profile of the trail grade...
-
4.1.2(7)
EXCEPTION: In multiple-story buildings and facilities where at-grade egress from each floor is impossible, either of the following is permitted: the provision within each story of approved...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
11B-604.7 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-404.2.11 Vision lights
or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish...
-
11B-404.2.11 Vision lights
or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish...
-
1. Sloped Surfaces
The amount of slope or grade is described as the proportion of a vertical rise to a horizontal length....
-
Scenario 6 – Disagreement Over Need to Evaluate
She maintains these grades even though she has been absent several times since the beginning of the school year for a gastrointestinal disorder....
- Hager Companies 4.5" Round Actuator 2-659-0165
- Hager Companies 6" Square Actuator 2-659-0169
-
Protruding objects and vitrines
Add aprons, extend bases, or add barriers below objects and vitrines that project more than 4" from walls and have their leading edges greater than 27" and less than 80" above the finished...
-
4.30.3 Character Height
Height Above Finished Floor Minimum Character Height Suspended or Projected Overhead in compliance with 4.4.2 3 in (75mm) minimum...
- Hager Companies 6" Round Actuator 2-659-0161
- Hager Companies 4.5" Square Actuator 2-659-0172
- Hager Companies 1.5" x 4.75" Jamb Actuator 2-659-0176
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
407.2.1.1 Height
EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline of the highest operable...
-
604.9.5 Flush Controls
Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
-
604.9.5 Flush Controls