Signs with tactile characters shall comply with Section 11B-703.4.
Search Results "Exit Door"
Commonly Searched Documents
- 
    
  
  11B-703.4 Installation height and location
  
 - 
    
  
  11B-703.5.7 Stroke thickness
  
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
 - 
    
  
  907.2.2 Group B
  
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
 - 
    
  
  Requirement 3 -- Usable Doors
  
[See subsections ...]
 - 
    
  
  1009.8 Two-way communication
  
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
 - 
    
  
  Guest Rooms
  
This applies to all doors, including bathroom doors that allow full user passage....
 - 
    
  
  1132A.9 Smooth surface
  
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
 - 
    
  
  1132A.9 Smooth surface
  
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
 - 
    
  
  1132A.9 Smooth surface
  
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
 - 
    
  
  1007.2 Continuity and components
  
1007.2 Continuity and components. Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
 - 
    
  
  1009.2 Continuity and components
  
Each required accessible means of egress shall be continuous to a public way and shall consist of one or more of the following components:
 - 
    
  
  T502 Doorways
  
[See subsections ...]
 - 
    
  
  § 38.93 Doorways
  
[56 FR 45756, Sept. 6, 1991, as amended at 76 FR 57939, Sept. 19, 2011]
 - SDC S6000 Spectra Exit Devices
 - 
    
  
  Toilet Compartment Access
  
If you look at 604.8.1.2 Doors, it says, "Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment...
 - 
    
  
  2. a. ii. Accessible entrance and exit route
  
[See subsections ...]
 - 
    
  
  § 38.113(c) Signals
  
If doors to the platform close automatically or from a remote location, auditory and visual warning signals shall be provided to alert passengers of closing doors...
 - CS Pocket Insert Track Demo
 - DORMA 8000 Series Exit Device
 - Horton Automatics Product Slideshow
 - EZConcept – Global Architectural Solutions
 - 
    
  
  Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
  
They must provide direct access to an exit stairway (or to an elevator equipped with standby power). Horizontal exits can substitute for areas of refuge....
 - Sargent 8800 Rim Exit Device
 - 307.4 Door Opening Vertical Clearance
 
              