The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008....
Search Results "Exit Door"
-
1132A.7 Type of lock or latch
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008....
-
Building Entrance
At least one door at the accessible entrance must have a minimum clear width of 32 inches for a voter who uses a wheelchair or other mobility device to pass through the doorway....
-
1009.4 Elevators
Areas of refuge are not required for elevators accessed from a refuge area in conjunction with a horizontal exit....
-
11B-603.2.3 Door swing
11B-603.2.3 Door swing. Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-603.2.3 Door swing
Other than the door to the accessible water closet compartment, a door in any position, may encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-603.2.3 Door swing
[2010 ADA Standards] 603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture....
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008....
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
-
1003.2.13.3 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1003.2.13.5 or a horizontal exit. Exceptions: 1....
- Panda S.81 All Aluminum Multi-Slide Door System Corner Detail
- Panda S.11 Lift & Slide Wood Clad Radius Pocket Door System
- Panda TS.83 Thermally Broken Multi-Slide Door System Corner Detail
- Panda S.90 All Aluminum Slim Profile Multi-Slide Door System
-
803.3 Door Swing
803.3 Door Swing. Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing....
-
Is additional latch side clearance required on the push side of doors with a forward approach when either a latch or closer (but not both) is provided?
No, latch clearance 12” minimum is required for forward approaches on the push-side of doors equipped with both a closer and a latch....
-
T503.4 Steps at Other Doorways
The walking surface on steps serving all other non-rail vehicle doorways shall be lighted at all times with 2 foot-candles (22 lux) minimum of illumination.
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Most wheelchair users need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on. If the...
-
A4.2.1(1) Space Requirements for Wheelchairs
(1) Space Requirements for Wheelchairs. Many persons who use wheelchairs need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered...
-
§ 38.73 Doorways
[See subsections ...]
-
§ 38.53 Doorways
[See subsections ...]
-
1. Clear Width
Do bathroom doors in accessible guestrooms allow at least 32" of clear passage width to accommodate persons who use wheelchairs, walkers and other mobility aids?...
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
Signs: ADA Standard Section 703
[See subsections ...]