Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
Search Results "Exit Door"
-
11B-404.3.6 Break out opening
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and maneuvering...
-
Visual Notification Devices
Visual Notification Devices Care must be taken that notification devices intended to signal a door knock or bell are separately wired....
- Motorized Lift & Slide Door System by Panda
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
- CaviLock CL100 LaviLock
- Sargent AL 80 Alarmed Exit Panic Door Hardware
- How To Use the Door Closing Speed Tool
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall comply with Section 11B-705.1.2.2.
-
11B-705.1.2.2 Curb ramps
Detectable warnings at curb ramps shall comply with Section 11B-705.1.2.2.
-
Work Areas [4.1.1(3)]
Note that an accessible route through one work area ("research,") may be needed to provide access to an exit as part of an accessible means of egress....
-
§ 38.153 Doors, steps and thresholds
[56 FR 45756, Sept. 6, 1991, as amended at 63 FR 51698, 51702, Sept. 28, 1998]
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
Can doors swing into required clear floor or ground space?
Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
-
Kickplates
Kickplates Recommendation: Some people with disabilities may use walkers or wheelchair footrests to push through doors, particularly those with closers....
- Access Board: Doors in a Series
-
Egress Stairs
The requirement for a minimum 48 inch width between handrails is specific to stairs adjacent to areas of rescue assistance and does not apply generally to stairs covered by 4.9.
-
4.1.3(8)(b)(ii)
(ii) If access is provided for pedestrians from a pedestrian tunnel or elevated walkway, one entrance to the building from each tunnel or walkway must be accessible.
-
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width.
Error/Omission: Doors into and within guest rooms that are not accessible guest rooms do not provide at least 32" clear opening width....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
4.34.2(6)
(6) Doors to and in accessible spaces that are intended for passage shall comply with 4.13, except that the provisions of 4.13.9 apply only to the doors at accessible entrances to the unit...
-
7a.
Is the clear width for the door opening at least 32 inches measured when the door is open 90 degrees? [ADA Stds 4.1.3(7), 4.13.5] Yes _____ No _____...
-
404.3.3 Thresholds