[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 _|Operable Parts|_ in the area of refuge shall activate both a light in the area of refuge...
Search Results "Emergency Button"
Commonly Searched Documents
-
1007.8.1.1 Visible communication method
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
Multiple audio tracks playing at the same time
They also suggested a headset option or a pause button....
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
Cells with Communication Features: ADA Standard Section 232.2.2
Section 232.2.2 covers scoping requirements in the current ADA Standards for cells with communication features.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension....
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension....
-
1009.4.1 Standby power
The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....
-
11B-704.3 Volume control telephones
Most are operated by pressing a button or key....
-
409.4.6 Car Controls
Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush....
-
409.4.6 Car Controls
Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush....
-
Resources:
evacuation options Emergency Health Information June Kailes [2011 Edition 2], in PDF, Microsoft Word. contents include: create your emergency health information...
-
Door and Signal Timing
This provision helps ensure that elevator doors remain open long enough for persons with disabilities to travel from call buttons to the responding car and is based on a travel speed of...
-
11B-232.2.2 Cells with communication features
At least 2 percent, but no fewer than one, of the total number of general holding cells and general housing cells equipped with audible emergency alarm systems and permanently installed...
-
General: ADA Standard Section 215.1
Section 215.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for fire alarm systems.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension....
- Harmar CPL Commercial Vertical Platform Lift
- Cavity Sliders CL100 ADA LaviLock Hardware Set with 'Vacant / In Use' Indicator
-
233.3.1.2.1 Private Sites Provided by Occupant of Unit, F233.4.1.2.1 Private Sites Provided by Occupant of Unit
Where emergency transportable housing units are installed on private sites provided by the occupant of the unit, entities shall provide emergency transportable housing units with mobility...
-
Check Optional Features, if available
Check Optional Features, if available Pushbutton information message - Press the pushbutton for an extended button press to see if the pushbutton information message plays and that it...
-
FAQ: How do I enter a New Document in my Corada WorkSpace?
Adjust this setting by clicking the blue 'Edit' button to the right....
-
Resources:
Emergency Evacuation Planning Guide for People with Disabilities, 2016, National Fire Protection Agency Emergency Evacuation Preparedness: Taking Responsibility for Your Safety, A Guide...