When the accessibility function button is pressed, the audio output shall provide a verbal announcement of the floors served by the elevator group....
Search Results "Emergency Button"
-
11B-411.2.1.6 Identification of floors served
-
11B-411.2.1.6 Identification of floors served
When the accessibility function button is pressed, the audio output shall provide a verbal announcement of the floors served by the elevator group....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension....
-
[2010 ADAS] 105.2.2 ASME
ASME A17.1 requires a two-way means of emergency communications in passenger elevators....
-
[2010 ADAS] 105.2.2 ASME
ASME A17.1 requires a two-way means of emergency communications in passenger elevators....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
-
11B-807.3.1 Alarms
Where audible emergency alarm systems are provided to serve the occupants of cells, visible alarms complying with Section 11B-702 shall be provided....
- Step Hear Call Hear CH-100
-
407.4.6.2.1 Size
Buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension....
-
407.4.6.2.1 Size
Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
1007.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 _|Operable Parts|_ in the area of refuge shall activate both a light in the area of refuge...
-
407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1370 mm) maximum above the...
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
Multiple audio tracks playing at the same time
They also suggested a headset option or a pause button....
-
11B-407.4.6.1 Location
Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum above the...
-
Cells with Communication Features: ADA Standard Section 232.2.2
Section 232.2.2 covers scoping requirements in the current ADA Standards for cells with communication features.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension....
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension....
-
1009.4.1 Standby power
The elevator shall meet the emergency operation and signaling device requirements of California Code of Regulations, Title 8, Division 1, Chapter 4, Subchapter 6, Elevator Safety Orders....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....