Section 206.7.2 covers scoping requirements in the most current ADA Standards for accessible routes to wheelchair spaces.
Search Results "Patient Seated in Wheelchair"
-
Wheelchair Spaces: ADA Standard Section 206.7.2
-
2. Equipment Clearances for Breast Platforms
The MDE NPRM proposed knee and toe clearance requirements for diagnostic equipment used by patients seated in wheelchairs that paralleled the knee and toe clearance requirements from the...
-
11B-802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS
11B-802 Wheelchair spaces, companion seats, and designated aisle seats and semi-ambulant seats [2010 ADAS] 802 Wheelchair Spaces, Companion Seats, and Designated Aisle Seats...
-
11B-802 Wheelchair spaces, companion seats, and designated aisle seats and semi-ambulant seats
11B-802 Wheelchair spaces, companion seats, and designated aisle seats and semi-ambulant seats [2010 ADA Standards] 802 Wheelchair Spaces, Companion Seats, and Designated Aisle Seats ...
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
The MDE NPRM proposed knee and toe clearance for diagnostic equipment used by patients seated in wheelchairs to allow for components in the wheelchair space which the patient could approach...
-
5.8.2.4 Unobstructed Floor Space Recommendation
While discussing these issues, the Committee also considered positioning methods for patients using wheelchairs....
-
M302.1 General
Diagnostic equipment that supports patients in a seated position shall comply with M302. ...
-
4.1.2 Number of Wheelchair Seating Spaces
Each picnic table shall have at least one wheelchair seating space....
-
5.5.1 Armrest Provision for Equipment Used by Patient in Seated Position
5.5.1 Armrest Provision for Equipment Used by Patient in Seated Position. Armrests are not required but if provided cannot obstruct transfer supports....
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3....
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3....
-
11B-802 Wheelchair spaces, companion seats, and designated aisle seats and semi-ambulant seats
[2010 ADAS] 802 Wheelchair Spaces, Companion Seats, and Designated Aisle Seats...
-
M303.2.4.2.1 Depth
Wheelchair spaces shall include knee and toe clearance 17 inches (430 mm) deep minimum and 25 inches (635 mm) deep maximum....
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
M302.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a seated position must comply with the technical requirements of proposed section M302....
-
11B-221.2.2 Integration
The requirement that wheelchair spaces be an "integral part of the seating plan" means that wheelchair spaces must be placed within the footprint of the seating area....
-
11B-221.2.2 Integration
The requirement that wheelchair spaces be an "integral part of the seating plan" means that wheelchair spaces must be placed within the footprint of the seating area....
-
Team Player Seating Areas
Team Player Seating Areas Where provided, fixed team or player seating areas must contain the number of wheelchair spaces and companion seats required by ADAAG (based on the number of...
-
5.8.3.1 Breast Platform Height Recommendations
Another member emphasized the importance of considering patients of short stature in addition to considering patients seated in a wheelchair....
-
Whenever more than 300 seats are provided, wheelchair seating locations must be provided in more than one location.
• Whenever more than 300 seats are provided, wheelchair seating locations must be provided in more than one location. This is known as dispersed seating....
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction...
-
M302.3.2 Armrests
Where diagnostic equipment is used by patients in a seated position, armrests shall be provided. Advisory M302.3.2 Armrests....
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a transition...
-
Base Support [No specific provision—affects M303.2.4]
It does obstruct the floor space in front of the gantry and, thus, may limit how close a wheelchair can get to the equipment....