Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
Search Results "Forward Reach"
-
A4.2.5 & A4.2.6 REACH
-
A4.27.3 HEIGHT
Fig. A6 further illustrates mandatory and advisory control mounting height provision for typical equipment. Note distinction between built-in equipment (considered real property) and...
-
407.12.1.2 Vertical Plane for Forward Reach
Where a forward reach is provided, the vertical reference plane shall be 30 inches (760 mm) long minimum. Figure 407.12.1...
-
407.12.3 Forward Reach
Operable parts of ICT providing a forward reach shall conform to 407.12.3.1 or 407.12.3.2. The vertical reference plane shall be centered, and intersect with, the operable part....
-
407.12.3.1 Unobstructed Forward Reach
Where the operable part is located at the leading edge of the maximum protrusion within the length of the vertical reference plane of the ICT, the operable part shall be 48 inches...
-
407.12.3.2 Obstructed Forward Reach
The maximum allowable forward reach to an operable part shall be 25 inches (635 mm). Figure 407.12.3.2...
-
407.12.3.2.1 Height
Table 407.12.3.2.1 Operable Part Height Table 407.12.3.2.1 Operable Part Height Reach Depth Operable Part Height Less than 20 inches (510 mm) 48...
-
407.12.3.2.2 Knee and Toe Space
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of...
-
A4.2.5 & A4.2.6 Reach
Reach ranges for persons seated in wheelchairs may be further clarified by Fig. A3(a)....
-
A4.27.3 Height
Electrical receptacles installed to serve individual appliances and not intended for regular or frequent use by building occupants are not required to be mounted within the specified reach...
-
308.2 Forward Reach
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2 Forward reach
-
11B-308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1219 mm) maximum and the low forward reach shall be 15 inches (381 mm) minimum above the finish floor or...
-
11B-308.2.2 Obstructed high reach
The high forward reach shall be 48 inches (1219 mm) maximum where the reach depth is 20 inches (508 mm) maximum....
- 308.2.1 Hand Dryer Reach Range Forward Unobstructed
- 309.3 Baby Changing Table Pull Down Handle Height
- Access Board: Obstructed Forward Reach
- Access Board: Unobstructed Forward Reach
- At your service. A 20 minute film. Engage customers with disabilities.
- Figure 308.2.1 Unobstructed Forward Reach – Drawing from the U.S. Access Board