Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
Search Results "Residential Structure"
-
11B-809.10.7.3 Reinforcement for grab bars
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.5.3 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4. Exception: Shower spray units are not required in bathtubs.
-
11B-809.8.1 Door Thresholds
Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5. Secondary exterior door thresholds,...
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
Seats: ADA Standard Section 608.4
Section 608.4 covers the current ADA Standards for seats in shower compartments.
-
11B-202.4 Path of Travel Requirements in Alterations, Additions and Structural Repairs
SECTION TITLE NOTES 11B-202.4 Path of Travel Requirements in Alterations, Additions and Structural Repairs...
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
Washing Machines; Clothes Dryers— Sections 214.2 and 214.3 of the 2010 Standards
UFAS requires front loading washing machines and clothes dryers in common use laundry rooms in facilities serving accessible residential dwelling units.20 UFAS’ requirements for front-loading...
-
California DSA: Valuation Threshold for Alterations, Structural Repairs or Additions to Existing Buildings
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (...
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914...
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914...