B5. Are all accessible parking spaces, including the access aisle, relatively level (1:50 or 2%) in all directions? [ADA Standards § 4.6.3] Yes No If No: Look for a...
Search Results "Shower Slope"
Commonly Searched Documents
-
B5
-
7.4.4 Resting Intervals
Resting intervals shall comply with 7.4.4. Where the trail grade exceeds 1:20 (5 percent), resting intervals shall be provided as specified in Table 7.4.3.1.
-
6.7.1.1
The grade of a Beach Access Route shall be 1:20 (5 percent) or less for any distance.
-
Department of Justice method
Department of Justice method In the tips and techniques section of "Survey Tools and Techniques," (www.usdoj.gov/crt/ada/ckstools.htm) the checklist states that slopes can be measured...
-
4.1.7(3)(a)
EXCEPTION: A ramp with a slope no greater than 1:6 for a run not to exceed 2 ft (610 mm) may be used as part of an accessible route to an entrance....
-
4.1.7(2)(a)
EXCEPTION: A ramp with a slope no greater than 1:6 for a run not to exceed 2 ft (610 mm) may be used as part of an accessible route at an entrance....
-
11B-502.4 Floor or ground surfaces
Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 502.4 Floor or Ground Surfaces. ...
-
11B-502.4 Floor or ground surfaces
Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 502.4 Floor or Ground Surfaces. ...
-
Accessible Sidewalks 1: Pedestrians who use Wheelchairs
Requires the Registered User plan or above. Login!
-
304.2 Floor or Ground Surfaces
EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surface Exception....
-
A4.5.1 General
Cross slopes on walks and ground or floor surfaces can cause considerable difficulty in propelling a wheelchair in a straight line....
-
9.1.2 Accessible Units, Sleeping Rooms, and Suites
In addition, in hotels, of 50 or more sleeping rooms or suites, additional accessible sleeping rooms or suites that include a roll-in shower shall also be provided in conformance with the...
-
304.2 Floor or Ground Surfaces
EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
-
11B-304.2 Floor or Ground Surfaces
Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
-
304.2 Floor or Ground Surfaces
[ECTCR UFAS 4.2.4.3] EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 304.2 Floor or Ground Surfaces Exception....
-
11B-304.2 Floor or Ground Surfaces
Exception: Slopes not steeper than 1:48 shall be permitted. [2010 ADAS] Advisory 304.2 Floor or Ground Surfaces Exception. ...
-
11B-304.2 Floor or ground surfaces
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. Advisory 11B-304.2 Floor or ground surface Exception....
-
Technical Memorandum TM 2013-10 Clustered Toilet Rooms
Access Board, TAS 213.2, Exception 4 does not apply to multiple single user bathing or shower rooms; therefore, this Exception is applicable only to multiple single user toilet rooms clustered...
- SafePath SafeShower™ Ramp Transitions
-
§ 38.83(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform...
- Symmons Hand Shower T-600B-36-V
- ACO Premium Linear QuARTz Drain
-
Are side flares required at curb ramps?
The ADA Standards do not require that curb ramps have side flares, but limit the slope (1:10 max.) where they are provided....
- Figure 610.3.1 Rectangular Shower Seat – Drawing from the U.S. Access Board