Search Results "Power Operated Door"
-
1.4.4. Operational Requirements
-
1007.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with the emergency operation and signaling device requirements of California Code of Regulations...
-
4.5.5 Controls and Operating Mechanisms
Controls and operating mechanisms shall comply with the operable parts requirements in sections 308 and 309.4 of the ABAAS. Exception....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
11B-707.3 Operable parts
Operable parts shall comply with Section 11B-309....
-
11B-707.3 Operable parts
Operable parts shall comply with Section 11B-309....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Smooth Surface
Exceptions from this requirement are recognized for sliding doors (Exception 1), certain tempered glass doors without stiles (Exception 2), doors and gates that do not extend to within 10...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
Operable Parts
Components of diagnostic equipment that are used by the patient to activate, deactivate, or adjust the equipment.
-
Operable Parts
A component of diagnostic equipment that is used by the patient to activate, deactivate, or adjust the equipment.
-
Staff Training
include instruction on the types of OPDMDs that can be accommodated, the rules for obtaining credible assurance that the device is being used because of a disability, and the rules for operation...
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
- DORMA ED100/250 Swing Door Operator
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
Amenities
Doors shall not swing into the clear floor space required by 903.2. 404 Doors, Doorways, and Gates. 404.2.3 Clear Width. Door openings shall provide a clear width of 32 inches minimum....
-
703.4.2 Location
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
302.4 Without Hearing
Where an audible mode of operation is provided, ICT shall provide at least one mode of operation that does not require user hearing....
-
302.4 Without Hearing
Where an auditory mode of operation is provided, ICT shall provide at least one mode of operation that does not require user hearing....
-
Entrances
space beyond the latch side of the door....