The 1991 Standards do not allow an in-swinging door in a toilet or bathing room to overlap the required clear floor space at any accessible fixture....
Search Results "Clear Floor Space"
Commonly Searched Documents
-
Alterations and Water Closet Clearances in Single-User Toilet Rooms With In-Swinging Doors (Section-by-Section Analysis)
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. ...
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
Turning Space: ADA Standard Section 808.2
Where provided, areas that are raised or depressed and accessed by ramps or platform lifts with entry ramps shall provide unobstructed turning space complying with 304....
-
1013.2.1 Size
The clear ground space shall be 48 inches (1220 mm) wide minimum....
-
1013.2.1 Size
The clear ground space shall be 48 inches (1220 mm) wide minimum....
- Figure 403.5.1 Clear Width of an Accessible Route – Drawing from the U.S. Access Board
-
11B-802.1.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-411.4.11 Floor destination indicators
There shall be on each elevator car door jamb a visual display indicating floor destinations....
-
7(2)(b)
(b) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Clear floor space beside tub may overlap with clear floor space...
-
11B-411.1.1 Floor designations
In facilities served by destination-oriented elevator systems, floor designations shall be numeric characters only....
-
11B-302 Floor or ground surfaces
[See subsections ...]
-
11B-411.2.3.1 Floor designation signs
Floor designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
CLEAR
CLEAR. [DSA-AC] Unobstructed....
-
Floor and Ground Surfaces
This guide explains requirements in the ADA Standards for floor and ground surfaces. ...
-
Turning Space: ADA Standard Section 807.2.1
Turning space complying with 304 shall be provided within the cell....
-
Turning Space: ADA Standard Section 806.2.6
Turning space complying with 304 shall be provided within the guest room....
- Access Board: Single User Toilet Room Size and Layout
-
Maneuvering Space, Adjustable Cabinetry, Fixtures and Plumbing
The Committee intends that such space be usable by handicapped persons, but this does not necessarily require that a turning radius be provided in every situation....
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...