Turning space complying with Section 11B-304 shall be provided within the room....
Search Results "Transfer Space"
-
11B-805.2.3 Turning space
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301) The Committee recommends a minimum transfer surface size of 28 inches wide by 17 inches deep for stretchers located...
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
11B-604.3.1 Size
A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be provided in front of the water closet....
-
5.1.5 Floor Height
at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the clear ground space...
-
5.1.5 Floor Height
at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the clear ground space...
-
5.4.3 Transfer Support Height for M301 and M302
5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer surface...
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position
5.3.2 Transfer Sides for Equipment Used by Patients in a Supine, Prone, or Side-Lying Position....
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
transfer supports on tables with transfer depths of less than or equal to 24 inches and positioning supports for transfer depths greater than 24 inches....
-
R302.4 Passing Spaces
R302.4 Passing Spaces. Where the clear width of pedestrian access routes is less than 1.5 m (5.0 ft), passing spaces shall be provided at intervals of 61 m (200.0 ft) maximum....
-
Ground Surfaces: ADA Standard Section 1008.2.6
Ground surfaces on accessible routes, clear floor or ground spaces, and turning spaces shall comply with 1008.2.6. Advisory 1008.2.6 Ground Surfaces....
-
M305.2 Transfer Supports (Section-by-Section Analysis)
(Significant Changes – Transfer Supports), the Access Board strengthened the transfer support requirements and added additional requirements in the final rule to ensure that supports are...
-
T702.6 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
Users and Needs
Hospital patients, and especially nursing facility residents, due to their stature, reach, and strength characteristics, typically require the assistance of caregivers during transfer maneuvers...
-
R305.1.2 Dome Spacing
R305.1.2 Dome Spacing....
-
304 Turning Space
[See subsections ...]
-
Addendum G: Comparison of Transfer Abilities between Men and Women
The following figures G1 and G2 show the difference in transfer ability between men and women for high and low transfers....
-
705.1.2 Dome Spacing
705.1.2 Dome Spacing....
-
Types of Alternative Designs
Whirlpool baths were generally used, although these ranged from large, institutional whirlpool tubs without grab bars for transfer to walk-in-type tubs with grab bars that were based on...
-
CLEAR FLOOR SPACE
CLEAR FLOOR SPACE. [DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
Wheelchair Spaces
Wheelchair Spaces Maneuvering into wheelchair spaces is often easier from the front or back than from the side, especially where they are paired....
-
6. Clear floor space
Clear floor space: Adequate space is provided to approach the toilet from a variety of wheelchair transfer positions (i.e. diagonal or side approaches)....
-
Clear Floor or Ground Space
Clear Floor or Ground Space At least one clear floor or ground space (30 inches by 48 inches minimum) must be provided at each location that has a railing height of 34 inches maximum....