This procedure was repeated until the largest horizontal distance was reached. The maximum and minimum heights attainable with the largest horizontal distance were recorded. ...
Search Results "Maximum Reach Depth"
Commonly Searched Documents
-
Adjustable height/gap protocol
-
Grab Bars [4.20.4] and Controls [4.20.5]
Grab Bars [4.20.4] and Controls [4.20.5] Controls must be within reach from outside the tub and cannot interfere with the use of the grab bars....
-
BS8300:2001 Research
Footrest depth was measured from “front of wheelchair seat to the front of the toes” but an anatomical landmark on the toes was not identified and information was not provided about how...
- Southwestern Independent Living Center, Inc. (SILC) - Jamestown, NY
-
11B-604.8.3 Coat hooks and shelves
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
4.3.4 Knee and Toe Clearances
For example, the ADA-ABA has a sloped line indicating the depth of knee clearance at the plane of the knees and the depth somewhere above the ankles....
-
11B-809.10.7.1 Floor space
width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a water closet which extend 24 inches (610 mm) maximum...
-
11B-705.1.2.4 Bus stops
warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth...
-
Priority 4: Additional Access - Drinking Fountains, Public Telephones & Fire Alarms
Word Fillable Form (0.7MB) Word Non-Fillable Form (0.6MB) PDF Non-Fillable Form (0.4MB)
- 604.6 Flush Control Reach Range
-
Priority 3: Toilet Rooms
Word Fillable Form (2.4MB) Word Non-Fillable Form (2.2MB) PDF Non-Fillable Form (0.7MB)
-
Transfer Platform: ADA Standard Section 1009.5.1
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
4.34.6.6* RANGES AND COOKTOPS
The clear floor space may overlap the knee space, if provided, by 19 in (485 mm) maximum. The location of controls for ranges and cook-tops shall not require reaching across burners....
-
Verify Framing
Grab bar backing in toilet/shower rooms. 11B-604.5, 11B-607.4, 11B-608.3 Backing for grab bars in bathtub/shower rooms. 11B-610 Width and depth...
-
Forward Approach
The 17 to 19 inch clearance depth allows people using wheelchairs to pull up far enough under the unit to reach the spout....
-
Verify Framing
Grab bar backing in toilet/shower rooms. 11B-604.5, 11B-607.4, 11B-608.3 Backing for grab bars in bathtub/shower rooms. 11B-610 Width and depth...
-
Attachment J
Free-standing objects mounted on posts or pylons may overhang 12 inches maximum from 27 inches to 80 inches above the ground or finished floor. Standards § 4.4....
-
11B-502.4 Floor or ground surfaces
Accessible parking spaces and access aisles are required to be level (maximum 1:48 slope) in all directions to provide a surface for wheelchair transfer to and from vehicles. ...
-
11B-502.4 Floor or ground surfaces
Accessible parking spaces and access aisles are required to be level (maximum 1:48 slope) in all directions to provide a surface for wheelchair transfer to and from vehicles. ...
-
11B-502.4 Floor or ground surfaces
Accessible parking spaces and access aisles are required to be level (maximum 1:48 slope) in all directions to provide a surface for wheelchair transfer to and from vehicles....
-
1009.4.5 Grab Bars
Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....