Dining surfaces and work surfaces shall comply with Sections 11B-902.2 and 11B-902.3....
Search Results "Transfer Surface Height"
-
11B-902.1 General
-
11B-302 FLOOR OR GROUND SURFACES
[See subsections ...]
-
Common Questions (Floor and Ground Surfaces)
Common Questions
-
11B-302 Floor or ground surfaces.
[See subsections ...]
-
11B-302 Floor or ground surfaces
[See subsections ...]
-
Performance for Surface Firmness and Stability
Performance for Surface Firmness and Stability In addition to the visual inspection and calculation of the surface deficiency score, the firmness and stability of the surfaces were measured...
-
Stability or Stable Surface
Stability or Stable Surface. ...
-
Height: ADA Standard Section 407.2.1.1
Section 407.2.1.1 covers the current ADA Standards for the height of the elevator call controls.
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Vertical Surface Discontinuities
Vertical Surface Discontinuities. Vertical differences in level between two adjacent surfaces....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30 inches...
-
407.4.2 Floor Surfaces
407.4.2 Floor Surfaces. Floor surfaces in elevator cars shall comply with 302 and 303....
-
Cross Slope and Surfaces [4.8.6]
Ramp surfaces must comply with requirements for ground and floor surfaces and be "stable, firm, and slip-resistant." A specific level of slip-resistance is not mandated....
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
Based on the restructure of the transfer surface provisions, described above in Section IV.B.1.b....
-
4.2.2 Cooking Surface Height
The cooking surface shall be at least 15 inches (380 mm) and no more than 34 inches (865 mm) above the floor or ground surface. ...
-
11B-604.9.3 Height
11B-604.9.3 Height. The height of water closets shall be 11 inches (279 mm) minimum and 17 inches (432 mm) maximum measured to the top of the seat....