Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
Search Results "Telecommunications Equipment Manufacturer"
Commonly Searched Documents
-
M303.3.3 Ramped
-
M303.3.3.4 Edge Protection
Ramps with drop offs ½ inch (13 mm) or greater shall provide edge protection 2 inches (50 mm) high minimum on each side.
-
M303.2.5 Surfaces
Wheelchair space surfaces shall not slope more than 1:48 in any direction.
-
3. Exception to Ramp Running Slope
The Access Board agrees with the MDE Advisory Committee that additional allowances in the slope of ramp runs of diagnostic equipment used by patients seated in a wheelchair with raised platforms...
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus. ...
- DOE Dear Colleague" Letter: Equal Access to Extracurricular Athletics for Students with Disabilities (Jan. 25, 2013)
- Gateway to Gold Mobile App for U.S. Paralympics
-
Transfer Supports Location and Configuration M301.3 and M302.3
The shape (contours and curves along length for ergonomics, not cross sectional profile) was kept open to give manufacture flexibility in the design as the direction of positioning (i.e....
-
104.1.1 Construction and Manufacturing Tolerances
104.1.1 Construction and Manufacturing Tolerances....
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus....
-
11B-805.4.3 Turning space
A minimum of a 36-inch wide access shall be provided to and along each side of the bed, exam table, procedure table, gurney, lounge chair and/or equipment/apparatus....
-
3.5 Other Tips for Increasing Access
Think about where you will safely place your animal when you are using the equipment or swimming....
-
Covered Entities
Covered Entities Manufacturers of telecommunications equipment and customer premises equipment are required by §255 of the Telecommunications Act of 1966 to "ensure that the equipment...
-
1.3. Public Comments on Initial Regulatory Assessment and Department Responses
Currently, there is more than one manufacturer of the equipment necessary to provide captioning and audio description, and the cost for the equipment varies among the manufacturers. ...
-
11B-805 Medical care and long-term care facilities
Clear space complying with Section 11B-305.2 shall be provided as required for specific equipment. 11B-805.4.3 Turning space....
-
5.4.2.1 Transfer Support Length for Stretchers
5.4.2.1 Transfer Support Length for Stretchers. Transfer supports on stretchers should be a minimum of 15 inches long.
-
5.4.2.1 Transfer Support Length Recommendation for Stretchers
5.4.2.1 Transfer Support Length Recommendation for Stretchers On Stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are...
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers The Committee recommends locating the transfer support along the long side of the of the...
-
M301.3 Transfer Supports
M301.3 Transfer Supports Proposed requirement: Transfer supports shall be provided for use with the transfer sides required by M301.2.3 and shall comply with M305.2. •...
-
5.8.2.1 Height of Breast Platform At Time of Measurement
5.8.2.1 Height of Breast Platform At Time of Measurement. All knee and toe clearances should be measured when the top of the breast platform is set at 34 inches above the floor.
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface.
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers. Transfer supports should be located along the long side of the transfer surface on the opposite side of the...
-
5.3.2.1 Transfer Sides Recommendation for Stretchers
5.3.2.1 Transfer Sides Recommendation for Stretchers On stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine,...
-
F104.1.1 Construction and Manufacturing Tolerances