Elongated openings should be placed so that the long dimension is perpendicular, or as close to perpendicular as possible, to the dominant direction of travel....
Search Results "Maximum Dimension"
-
1011.2.4 Openings
-
§ 38.159(b)(2)(ii) Exception
Where the lift is designed to deploy with its long dimension parallel to the vehicle axis and which pivots into or out of the vehicle while occupied (i.e., “rotary lift”), the requirements...
- Door King Inc. 6050 / 6100 Residential and Commercial Swing Gate Operator
-
Can parking signage height be considered a "safe harbor"?
No specific height dimension given. For an older property with parking signs mounted at, say 45" inches to the bottom, are these protected by the safe harbor rule? ...
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
11B-608.5.3 Alternate roll-in type shower compartments
shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum and 27 inches (686 mm) maximum...
-
11B-608.5.3 Alternate roll-in type shower compartments
shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum and 27 inches (686 mm) maximum...
-
E101.4 Units of Measurement (Section-by-Section Analysis)
This proposed section is new to the 508 Standards and would clarify dimensions stated in the text of the proposed rule....
-
4.13.6 Maneuvering Clearances at Doors
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension “x” in Fig. 25) if the...
-
4.1.6(4)(c)
(ii) Where existing shaft or structural elements prohibit strict compliance with 4.10.9, then the minimum floor area dimensions may be reduced by the minimum amount necessary, but in no...
-
8. Boarding Separately From Wheelchair
(Note, however, that under § 37.165(b), entities are required to accommodate device/user loads and dimensions that exceed the former “common wheelchair” standard, as long as the vehicle...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
8. Boarding Separately From Wheelchair
(Note, however, that under §37.165(b), entities are required to accommodate device/user loads and dimensions that exceed the former “common wheelchair” standard, as long as the vehicle and...
-
Accessible Routes: ADA Standard Section 1007.2
Where accessible routes intersect playing surfaces of holes, a 1 inch (25 mm) maximum curb shall be permitted for a width of 32 inches (815 mm) minimum. 3....
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
-
11B-504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (12.7 mm) maximum....
-
11B-504.5 Nosings
The radius of curvature at the leading edge of the tread shall be ½ inch (12.7 mm) maximum....
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
- Spectrum Aquatics Traveler II XRC500 Pool Lift
- Bradley Security Grab Bars SA70 Series