Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
Search Results "Maximum Dimension"
-
11B-1009.3.2 Submerged depth
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum...
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
Location: ADA Standard Section 407.4.6.1
Section 407.4.6.1 covers the current ADA Standards for the location of elevator car controls.
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
Dispensers: ADA Standard Section 604.9.6
Section 604.9.5 covers the current ADA Standards for dispensers in children's use toilet compartments.
-
Bathtub Seats: ADA Standard Section 610.2
Section 610.2 covers the current ADA Standards for bathtub seats.
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
- Door King Inc. 6050 / 6100 Residential and Commercial Swing Gate Operator
-
Which transition type do users with disabilities prefer?
When a sidewalk slopes more than 2% in the direction of travel and a walk with a maximum 2% cross slope intersects it, which transition segment type provides the safest usability for the...
-
2. Analysis of footrest clearance height and depth
The range and median values measured on the right-side for these three dimensions are presented in table 2. Critical values are highlighted in yellow....
-
Height: ADA Standard Section 1008.3.2.2
Each transfer step shall be 8 inches (205 mm) high maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
Vertical: ADA Standard Section 303.2
Section 303.2 covers the current ADA Standards for vertical changes in level.
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....