(a) As a general rule, the accessibility provisions of part 4 shall be applied to "qualified" historic buildings and facilities. "Qualified" buildings or facilities are those...
Search Results "Toilet Compartment"
Commonly Searched Documents
-
4.1.7(1)(a)
-
11B-603.2.1 Turning space
11B-603.2.1 Turning space. Turning space complying with Section 11B-304 shall be provided within the room.
-
11B-603.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
Installation Height and Location: ADA Standard Section 703.4
Signs with tactile characters shall comply with 703.4.
-
Stroke Thickness: ADA Standard Section 703.5.7
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character.
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-703.4 Installation height and location
Signs with tactile characters shall comply with Section 11B-703.4.
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
-
Plumbing Elements and Facilities
[See subsections ...]
-
Water Closet Clearance
These commenters believed that the requirement will increase the usability of accessible single-user toilet rooms by making side transfers possible for many individuals who use wheelchairs...
-
F247.4.4 Routes
Routes that connect trails complying with 1017 to camping facilities, picnic facilities, viewing areas, pit toilets, and accessible elements provided within the facilities shall comply with...
-
11B-409.4.7.3 Compartment
If the telephone or device is in a closed compartment, the compartment door hardware shall comply with Section 11B-309....
-
Showers
Comments. Several commenters requested that the final Guidelines provide dimensions on the appropriate width and height of showers and shower doors. Another commenter asked whether...
-
§ 38.127(c)
(c) Controls and operating mechanisms (e.g., heating and air conditioning controls, lighting controls, call buttons, electrical outlets, etc.) shall be mounted no more than 48...
- Redi Free® with Redi Base® Shower Pans
- Redi Free® with Redi Trench® Shower Pans
-
Additions: ADA Standard Section 202.2
Section 202.2 covers the most current requirements for additions in existing building and facilities.
-
Character Proportions: ADA Standard Section 703.5.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
Character Spacing: ADA Standard Section 703.5.8
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
- American Specialties Recessed Bedpan and Urinal Bottle Storage Cabinet 0551