(B) For the purposes of this section, the term “path of travel” also includes the restrooms, telephones, and drinking fountains serving the altered area.
Search Results "Toilet Compartment"
Commonly Searched Documents
-
§ 35.151(b)(4)(ii)(B)
-
H27
H27. Does this 36-inch wide stall have horizontal grab bars on both of the side partitions that are at least 36 inches long and 33 to 36 inches above the floor? [ADA Standards §...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
M1
If a sign is provided at the toilet room entrance (e.g....
- AD Systems’ Patient Restrooms
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
This expert panel also estimated that single-user toilet rooms with out-swinging doors would be used slightly less than once every other visit to a facility with such toilet rooms covered...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
This expert panel also estimated that single-user toilet rooms with out-swinging doors would be used slightly less than once every other visit to a facility with such toilet rooms covered...
-
Guidelines for Requirement 2
protruding objects; ground and floor surface treatments; parking and passenger loading zones; curb ramps; ramps; stairs; elevator, platform lifts; drinking fountains and water coolers; toilet...
-
Tork Elevation® High Capacity Bath Tissue Roll Dispenser, Black
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Tork Elevation® High Capacity Bath Tissue Roll Dispenser, White Model
Requires the Premium User plan or above. (Login or upgrade your account!)
- Collapsible Water Retainer Shower Dam for Shower Threshold
- Bradley 2-Stall Seat Cover/Tissue Dispenser & Napkin Disposal 5911
-
Accessible Restrooms, Fitting Rooms, and Elevators
Maintenance List Unlock accessible public restrooms, toilet stalls, and fitting rooms and make sure they are available to customers with disabilities during business hours....
-
Willoughby Industries S-3636-HC Accessible Cabinet Shower
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60...
-
Signs: ADA Standard Section 703
[See subsections ...]
-
Signs: ADA Standard Section 216
Section 216 covers scoping requirements in the current ADA Standards for signs.
-
11B-216 Signs
[See subsections ...]
-
11B-703 Signs
[See subsections ...]
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.