The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum....
Search Results "Hinge Side Clearance"
Commonly Searched Documents
-
308.3.2 Obstructed High Reach
-
8. Gap
8. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
11. Gap
11. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
H. Drop-off Area Height
H. Is the height of the covered passenger pickup/drop-off area at least 9'−6" to allow vans with raised roofs to use such area? [ADA Stds. 4.6.5] Yes __ No __ N/A __ Comments:...
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
4.3.5 HEAD ROOM
Accessible routes shall comply with 4.4.2.
-
6.3(2)
(2) Each bedroom shall have adequate space to provide a maneuvering space that complies with 4.2.3. In rooms with 2 beds, it is preferable that this space be located between beds.
-
4.3.5 Head Room
Accessible routes shall comply with 4.4.2.
-
6.3(1)
(1) Each bedroom shall have a turning space that complies with 4.2.3, and preferably that is located near the entrance.
-
11B-308.3.2 Obstructed high reach
The high side reach shall be 48 inches (1219 mm) maximum for a reach depth of 10 inches (254 mm) maximum....
-
11B-809.10.4 Sufficient maneuvering space
The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures....
- Access Board: Maneuvering Clearance at Recessed Doors
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
d. Unobstructed Transfer
and the outer edge of the equipment on the side used for transfer,” that applies to both the long length (width) and short length (depth) transfer sides....
-
Beds: ADA Standard Section 224.3
Section 224.3 covers scoping requirements in the current ADA Standards for transient lodging guest room beds.
-
11B-604.7 Dispensers and disposal units
Toilet paper dispensers and sanitary napkin disposal units shall comply with Section 11B-604.7. Combination accessory units are not permitted to encroach into the space required by...
-
11B-224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with Section 11B-806.2.3.
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...