The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1‒1/4 in to 1‒1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface. If...
Search Results "Hinge Side Clearance"
-
4.26.2* Size and Spacing of Grab Bars and Handrails
-
1134A.8, Item 4.3
4.3. Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space. The knee and toe space shall be centered on...
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following:
-
1133A.7, Item 2
2. The knee and toe space shall be 30 inches (762 mm) wide minimum, centered on the sink, countertop or appliance.
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following: The knee and toe space shall be clear and unobstructed, or removable...
-
6.3(3)
(3) Each two-bed room shall have a minimum clear floor space of 42 in (1065 mm), preferably 48 in (1220 mm), between the foot of the bed and the wall; 36 in (915 mm) between the side of...
-
Error/Omission: No van accessible spaces are provided in the parking area.
The vertical clearance at such spaces shall comply with 4.6.5. All such spaces may be grouped on one level of a parking structure....
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
Suspicious Minds Ramp
The ramp leading to the exhibits has a rise greater than 6", but does not have the required handrails on both sides. See Standards § 4.8.5. q....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
1132A.4 Level floor or landing
The floor or landing on each side of a door shall be level....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
4.25.3 Height
Clothes rods or shelves shall be a maximum of 54 in (1370 mm) above the finish floor for a side approach....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment....
-
11B-809.8.3.1 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall not have slopes exceeding 1:48....
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
304 Turning Space
Section 304.3 permits turning space to include knee and toe clearance complying with section 306....