Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
Search Results "Hinge Side Clearance"
-
11B-409.3 Elevator doors
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-809.8.3.1 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall not have slopes exceeding 1:48....
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment....
-
304 Turning Space
Section 304.3 permits turning space to include knee and toe clearance complying with section 306....
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
D. Protruding Objects
D. Protruding Objects - Examine all interior hallways, stairways and other pedestrian routes: ...to minimize the risks to blind persons and persons with low vision, are all of...
-
A. Slope at Door
A. If a fully automatic door is not provided, is the walkway in front of the lobby door level, without any portion steeper than 1:50 (critical dimension of ´" or less), so persons...
-
4.8.4* Landings
Ramps shall have level landings at bottom and top of each ramp and each ramp run. Landings shall have the following features:
-
2. Adequate Space
2. Within the voting area, is adequate space available on the accessible level for check-in tables, a voting demonstration area (if provided), and at least one accessible voting...
-
4.8.4 LANDINGS
Ramps shall have level landings at the bottom and top of each run. Landings shall have the following features: (1) The landing shall be at least as wide as the ramp run leading to...
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
Plan 1B: 13-Foot Wide Accessible Guest Room
at lavatory (section 304.3); • Water closet clearance is 60 inches at back wall and 56 inches deep (section 604.3); • Centerline of the water closet at 16‒18 inches from side wall...
-
11B-609.3 Spacing
For L-shaped or U-shaped grab bars complying with Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
11B-609.3 Spacing
For L-shaped or U-shaped grab bars complying with Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
Shape and Diameter
The 1½ inch clearance between walls and handrails is an absolute dimension; it provides knuckle clearance while preventing entrapment of the arm for people who lean on rails with their forearm...
-
4.6.4 Clear Floor or Ground Space
Knee and toe clearance complying with ABAAS section 306 shall be provided under the telescope or periscope....
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....