Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum...
Search Results "Expected Maximum Flight Duration"
-
11B-407.4.6.1 Location
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
11B-809.12 Electrical receptacles, controls and switches
branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no obstruction, 48 inches (1219 mm) maximum...
-
Height: ADA Standard Section 1008.3.2.2
Each transfer step shall be 8 inches (205 mm) high maximum....
-
Vertical: ADA Standard Section 303.2
Section 303.2 covers the current ADA Standards for vertical changes in level.
-
Rise: ADA Standard Section 405.6
Section 405.6 covers the current ADA Standards for the rise requirements of ramps.
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
11B-405.6 Rise
The rise for any ramp run shall be 30 inches (762 mm) maximum....
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum....
-
11B-406.5.7 Cross slope
The cross slope of curb ramps and blended transitions shall be 1:48 maximum....
-
Parallel Approach: ADA Standard Section 904.4.1
A portion of the counter surface that is 36 inches (915 mm) long minimum and 36 inches (915 mm) high maximum above the finish floor shall be provided....
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.
-
11B-705.1.2.2.1 Perpendicular curb ramps
Detectable warnings shall extend the full width of the ramp run less 2 inches (51 mm) maximum on each side, excluding any flared sides....
-
11B-604.9.1 Location
The centerline of the water closet shall be 12 inches (305 mm) minimum and 18 inches (457 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (432...