In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
Search Results "Door Opening Force"
Commonly Searched Documents
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
SECTION 1010 DOORS, GATES AND TURNSTILES
[DSA-AC] In addition to the requirements of this section, means of egress, which provide access to, or egress from, buildings or facilities where accessibility is required for...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2....
-
Elevator Door Requirements [§407.3]
Elevator Door Requirements [§407.3]...
-
D2. Clear Passage
Does at least one door or one side of a double leaf door at the accessible entrance provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
4.8.4(4)
(4) If a doorway is located at a landing, then the area in front of the doorway shall comply with 4.13.6.
-
Controls [§404.3.5]
Controls [§404.3.5] Door and gate controls must be compliant as operable parts (operable with one hand and without tight grasping, pinching, twisting of the wrist, or more than 5 lbf)...
-
Building Entrance
At least one door at the accessible entrance must have a minimum clear width of 32 inches for a voter who uses a wheelchair or other mobility device to pass through the doorway....
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
-
§ 38.93(a)(1)
(1) At least one door on each side of the car from which passengers board opening onto station platforms and at least one adjacent doorway into the passenger coach compartment, if provided...
-
D6. Vestibule Clear Floor Space
[ADA Stds 4.13.7] Yes _____ No _____ If No, leave the inner door open or remove inner door, add power operators to both doors so they open at the same time or, modify the vestibule...
-
Door Swing [§304.4] and Other Space Requirements
Door Swing [§304.4] and Other Space Requirements Doors can swing into the turning space....
-
Multiple Usable Entrances
However, the requirements for usable doors and an accessible route to exterior spaces such as balconies and decks does respond to this concern....
-
Gaps
Gaps Where wheelchair spaces are provided on amusement rides, the floors of rides must be coordinated with the floors of the load and unload areas so that when the ride is at...
-
12162(a)(2)(D)(i)
(i) be able to be entered by an individual who uses a wheelchair;
-
§ 38.159(c)(6) Attachment
(6) Attachment. When in use for boarding or alighting, the ramp shall be firmly attached to the vehicle so that it is not subject to displacement when loading or unloading a heavy...
- Aurora Doors Sliding Barn Door
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
803 Dressing, Fitting, and Locker Rooms
In the proposed rule, an exception to this provision noted that a portion of this space (6 inches maximum) could extend under partitions or openings without doors that provide toe clearance...
- Norton Surface Mounted 5600 Hands-Free Door Operation Kits