Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
Search Results "Door Opening Force"
Commonly Searched Documents
-
404.2.8.2 Spring Hinges
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
- Mockett DH2 Door Handle Installation
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
Clear Width [4.13.5] and Vertical Clearance
Clear Width [4.13.5] and Vertical Clearance The clear width of the opening is measured from the face of the door in a 90 degrees open position to the opposite stop....
-
A4.2.1(1) Space Requirements for Wheelchairs
Most wheelchair users need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on....
-
A4.2.1(1) Space Requirements for Wheelchairs
Many persons who use wheelchairs need a 30 in (760 mm) clear opening width for doorways, gates, and the like, when the latter are entered head-on....
- NYC Board of Elections: Video 3 - Accessibility Clerk Responsibilities
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
6.3(1)
(1) Each bedroom shall have a door that complies with 4.13....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
10.3.1(9)
(9) In stations covered by this section, rail-to-platform height in new stations shall be coordinated with the floor height of new vehicles so that the vertical difference, measured...
-
11B-404.2.4 Maneuvering clearances
Minimum maneuvering clearances at doors and gates shall comply with Section 11B-404.2.4....
-
4.13.2 Revolving Doors and Turnstiles
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
4.13.2 REVOLVING DOORS AND TURNSTILES
Revolving doors or turnstiles shall not be the only means of passage at an accessible entrance or along an accessible route....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
- Besam SL500 A01 sliding door with outstanding performance
-
A. Movie Basics, Captioning, and Audio Description Generally
There are, at present, two types of captions available for movies: open captions and closed captions. ...
- Visitability
-
F206.4.1 Public Entrances
All public entrances provided in accordance with Paragraph F206.4.1 (Public Entrances) of the ABAAS must have at least one entrance door complying with Section 404.3 (Automatic and Power-Assisted...
-
§ 38.93(a)(2)
then such doorway shall have, to the maximum extent practicable in accordance with the regulations issued under the Federal Railroad Safety Act of 1970 (49 CFR parts 229 and 231), a clear opening...