Exterior walls shall be of materials permitted by the building type of construction....
Search Results "Back Wall"
-
704.4 Materials
- Mansfield Lavatory Grande Isle 2018HBNS
- Whitehall Mfg. Ligature Resistant Solid Surface Basin
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-411.2.1.1 Location
Hall call consoles shall be wall-mounted. On floors with a building entry, including parking and transfer levels, each hoistway entrance shall be adjacent to a hall call console....
-
11B-809.10.7.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from a wall or partition that is 54 inches (1372 mm) minimum in length....
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
Signage
Where permanent identification is provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
604.8.1.2 Doors
Doors shall be located in the front partition or in the side wall or partition farthest from the water closet....
-
14) Carpet and carpet tile
Carpet tile must have maximum combined thickness of pile, cushion, and backing height of 1/2" (§4.5.3)....
-
Technical Memorandum TM 2013-23 Storage (Not in Kitchens or Kitchenettes)
For purposes of compliance with TAS 225.2, the Department shall consider base and wall cabinets to be the same type of storage if designed the same (i.e. both have doors), used for the same...
-
Outdoor Rinsing Showers
Locate the clear space so that the shower pedestal or wall to which the showerhead is attached is at the center back of the clear space so that the water from the showerhead is directed...
-
Selecting a TTY
Another model provides a coupler, screen, and keyboard within an enclosure than can be installed next to a wall-mounted pay phone....
- Rebuilding Together Aurora - Aurora, IL
- Gamco Welded Frame Mirrors - A-Series
-
7.4.11.1 Clear Space
Trailhead signs shall be located centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) minimum clear floor or ground space....
-
§ 38.113(d)(3) Exception
Where platform set-backs do not allow the horizontal gap or vertical alignment specified in paragraph (d) (1) or (2), platform or portable lifts complying with §38.125(b) of this part, or...
-
1133A.4.1, Item 4
Finished flooring shall be extended to the wall beneath the sink and work surface....
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
- American Specialties Channel Frame Mirror 0620