Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the floor....
Search Results "Back Wall"
-
4.18.2 HEIGHT
-
11B-408.4.6 Car controls
Control panels shall be centered on a side wall....
-
11B-408.4.6 Car controls
Control panels shall be centered on a side wall....
-
Handrails
If handrails are mounted on walls, the clear space between the handrail and wall must be 1.5 inches....
-
4.26.2* Size and Spacing of Grab Bars and Handrails
If handrails or grab bars are mounted adjacent to a wall, the space between the wall and the grab bar shall be 1‒1/2 in (38 mm) (see Fig. 39(a), (b), (c), and (e))....
-
1.2 Q. Does the Fair Housing Act cover four one-story dwelling units that share common walls and have individual entrances?
A. Yes. The Fair Housing Act applies to all units in buildings consisting of four or more dwelling units if such buildings have one or more elevators; and ground floor dwelling units...
-
711.3.3 Ducts and air transfer openings
Penetrations of fire-resistance-rated walls by ducts and air transfer openings that are not protected with fire dampers shall comply with this section....
-
408.4.6 Car Controls
Control panels shall be centered on a side wall....
-
4.18.2 Height
Urinals shall be stall-type or wall-hung with an elongated rim at a maximum of 17 in (430 mm) above the finish floor....
-
11B-809.10.8.3 Cabinets
The finished floor shall extend to the wall under the lavatory....
-
NPRM
Suppose a passenger asks for a round trip from Point A to Point B and back to Point A, or asks for a trip from Point A to Point B to Point C, with a return to Point A....
-
7.2(2)(iii)
shelf attached to the main counter on which an individual with disabilities can write, and (2) use of the space on the side of the counter or at the concierge desk, for handing materials back...
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
406.8--Modification to 406 of Appendix D to 36 CFR Part 1191
warning shall extend the full width of the curb ramp (exclusive of flared sides) and shall extend either the full depth of the curb ramp or 24 inches (610 mm) deep minimum measured from the back...
- Access-Able Designs Bariatric Shower Bench SH-430-3SDL
-
1011.2.1 Size and Location
Constructed Feature Minimum Size and Location Picnic tables 36 inches (915 mm) on all usable sides of the table measured from the back...
-
F105.2.2 ASME
require that at least two flat steps be provided at the entrance and exit of every escalator and that steps on escalators be demarcated by yellow lines 2 inches wide maximum along the back...
-
Contrast and wayfinding, short-term and long-term
Responses by [three Participant]: The majority of stairs in building are back of house. They’re really egress stairs. So they’re unfinished....
-
1011.2.1 Size and Location
Space Outdoor Constructed Feature Minimum Size and Location Picnic tables 36 inches (915 mm) on all usable sides of the table measured from the back...
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
604.8.2.3 Grab Bars
A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
704.2.1 Types I and II construction
Projections from walls of Type I or II construction shall be of noncombustible materials or combustible materials as allowed by Sections 1406.3 and 1406.4....