R402 Protruding Objects
Search Results "Kitchen Clearance"
Commonly Searched Documents
-
R402 Protruding Objects
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).
-
1010.1.5 Floor elevation
There shall be a floor or landing on each side of a door. Such floor or landing shall be at the same elevation on each side of the door. Landings shall be level except for exterior...
-
Forward Approach
Forward Approach Knee and toe clearances specified for lavatories in 4.19, which recognize space for plumbing (see page 75), can be applied to sinks....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
-
407.8.3.2.2 Knee and Toe Space under ICT with Obstructed Forward Reach
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of...
-
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis)
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis) This section proposes dimensions for knee and toe space under ICT when an obstructed forward reach is provided. The...
-
407.12.3.2.2 Knee and Toe Space
Knee and toe space under ICT shall be 27 inches (685 mm) high minimum, 25 inches (635 mm) deep maximum, and 30 inches (760 mm) wide minimum and shall be clear of...
-
Entrance Landings
Entrance landings must accommodate door maneuvering clearances as well as landings for provided ramps. Entrance Landing...
-
Clearances between a handrail and wall surface: 2012 NFPA 101 vs. 2010 ADA
Question/Issue: According to the new 2012 NFPA 101 Life Safety Code, Chapter 7, Section 7.2.2.4.4.5 & Exhibit 7.97, the finger clearance at an existing stair handrail should be...
-
Boat Slip Clearance: ADA Standard Section 1003.3.1
Advisory 1003.3.1 Boat Slip Clearance Exception 3....
-
4.1.3 Wheelchair Seating Space
Toe clearance of at least 9 inches (230 mm) in height shall extend at least an additional 5 inches (125 mm) from the knee clearance....
-
606.2 Clear Floor Space
A parallel approach complying with 305 shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided and to wet bars. 2....
-
606.2 Clear Floor Space
A parallel approach complying with 305 shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided and to wet bars. 2....
-
Doors
Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
-
5.8.2.5 Toe Height Recommendation
Rationale for the recommendation The NPRM defined the toe clearance at a height of 9 inches. However, as the breast platform moves up and down, it may intrude on the toe space....
-
Doorways at Landings [§405.7.5]
Doorways at Landings [§405.7.5] Required door maneuvering clearances can overlap ramp landings (it is advisable to locate the swing of doors outside ramp landings for greater safety)....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground. The clear floor or ground...
-
804.6.6 Refrigerator/Freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground. The clear floor or ground...
-
1133A.2, Item 3
3. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required...
-
804.6.6 Refrigerator/Freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground. The clear floor or ground...
-
804.6.6 Refrigerator/Freezer
804.6.6 Refrigerator/Freezer. Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground....
-
1133A.4.1 Repositionable countertops
Repositionable countertops shall be provided in a minimum of 5 percent of the covered multifamily dwelling units. Repositionable countertops shall comply with the following: