Faucet controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force required to activate...
Search Results "Dwelling Unit (FHA)"
-
1133A.6 Kitchen sink faucet controls
-
1133A.2 Clear floor space
Clear floor space at kitchens shall comply with the following: A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a...
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. Swinging doors shall provide a net clear opening width of not less...
-
M101.7 Units of Measurement
Measurements are stated in U.S. customary and metric units....
-
E101.4 Units of Measurement
Measurements are stated in metric and U.S. customary units....
-
C101.4 Units of Measurement
Measurements are stated in metric and U.S. customary units....
-
E101.4 Units of Measurement
Measurements are stated in metric and U.S. customary units....
-
C101.4 Units of Measurement
Measurements are stated in metric and U.S. customary units....
-
F208.3.2 Residential Facilities
In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with F208.2.3.1...
-
208.3.2 Residential Facilities
In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with 208.2.3.1...
-
208.3.2 Residential Facilities
In residential facilities containing residential dwelling units required to provide mobility features complying with 809.2 through 809.4, parking spaces provided in accordance with 208.2.3.1...
-
4.1.3(1) ELEVATORS
Elevators or other accessible means of vertical movement are not required in residential facilities when: (a) No accessible dwelling units are located above or below the accessible grade...
-
Section 35.151(e) Social Service Establishments (Section-by-Section Analysis)
For the first time, residential dwelling units are explicitly covered in the 2004 ADAAG in section 233. ...
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (...
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914...
-
11B-604.3.1 Size
Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914...
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
Seats: ADA Standard Section 608.4
Section 608.4 covers the current ADA Standards for seats in shower compartments.
-
F233.3.3 Alterations
EXCEPTION: Where compliance with 809.2, 809.3, or 809.4 is technically infeasible, or where it is technically infeasible to provide an accessible route to a residential dwelling unit, the...
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
11B-809.8.2 Door opening force
Doors shall comply with Section 11B-404.2.9. Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-215.5 Residential facilities
Where provided in residential dwelling units required to comply with Section 11B-809.5, fire alarms shall comply with Chapter 9, Section 907.5.2.3.4 and carbon monoxide alarms shall comply...