Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm) minimum....
Search Results "Boarding Ramp"
-
406.4 Landings
-
11B-1007.2 Accessible routes
Ramp landing slopes specified by Section 11B-405.7.1 shall be permitted to be 1:20 maximum. 5. ...
-
11B-1007.2 Accessible routes
Ramp landing slopes specified by Section 11B-405.7.1 shall be permitted to be 1:20 maximum. 5....
-
6. Ramps
Ramps 4.8 Accessible routes with slopes greater than 1:20....
-
Bus Stop Pads
Comments noted that this reference has been misinterpreted as applying to the vehicle space for buses which are sometimes provided with concrete pads, instead of to adjacent boarding areas...
-
406.4 Landings
Landings shall be provided at the tops of curb ramps. The landing clear length shall be 36 inches (915 mm) minimum....
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
Slide Board Wheelchair Transfer
Requires the Registered User plan or above. Login!
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
Fittings: ADA Standard Section 505.9
Section 505.9 covers the current ADA Standards for handrail fittings.
-
11B-505.9 Fittings
Handrails shall not rotate within their fittings.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved.
-
11B-505.9 Fittings
Handrails shall not rotate within their fittings.
- GameTime ADA Wide Ramp Attachment 3D
-
R308.1.1.2 Grade
Parallel to the street or highway, the grade of boarding and alighting areas shall be the same as the street or highway, to the extent practicable....
-
§ 38.125(c) Car ramp or bridge plate
(c) Car ramp or bridge plate—...
-
9. When ramp access is provided to one side of a crawl tube and the other side is only entered by transfer access, how is it counted (ramp or transfer access play component)?
When ramp access is provided to one side of a crawl tube and the other side is only entered by transfer access, how is it counted (ramp or transfer access play component)?...
-
1.1.12 Ramp cross slope
1.1.12 Ramp cross slope....
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
11B-810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2438 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
DSA Drawing 11B-406-8C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)