It appears that this comment references the 2010 ADA Standards for Accessible Design for minimum bench length (42") but uses the CA - 2013 minimum bench length (48") to develop the minimum...
Search Results "Accessible Space"
-
Minimum Rear Wall Required.
-
Existing elevator cab size
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
- Inclusion Solutions Pakflatt® Franklin® Voting Booth
-
5.1* General
dining counters where food is consumed but there is no service) are provided, at least 5 percent, but not less than one, of the fixed tables (or a portion of the dining counter) shall be accessible...
-
Alterations [4.1.6(1), (2)]
Alterations [4.1.6(1), (2)] In alterations, access is required where toilet or bathing facilities are altered....
- Figure 607.4.1 Grab Bars for Bathtubs with Permanent Seats – Drawing from the U.S. Access Board
- Steelcase OLOGY Desk - Electric Rectangular Desk with Rail, Power Access and Up/Down Controller
- Figure 505.10.1 Top and Bottom Handrail Extension at Ramps – Drawing from the U.S. Access Board
- Figure 505.6 Horizontal Projections Below Gripping Surface – Drawing from the U.S. Access Board
- Figure 505.7.2 Handrail Non-Circular Cross Section – Drawing from the U.S. Access Board
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.01 DC70-BP
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.02 DC70-SS
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.50 DC7-TD
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.03 DC70TL-BP
Requires the Premium User plan or above. (Login or upgrade your account!)
- Figure 904.4 (Exception) Alteration of Sales and Service Counters – Drawing from the U.S. Access Board
- Figure 302.3 Elongated Openings in Floor or Ground Surfaces – Drawing from the U.S. Access Board
- Figure 810.2.2 Dimensions of Bus Boarding and Alighting Areas – Drawing from the U.S. Access Board
- Figure 608.3.1 Grab Bar for Transfer Type Showers – Drawing from the U.S. Access Board
- Figure 404.2.4.3(a) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
- Figure 406.6 Diagonal or Corner Type Curb Ramps – Drawing from the U.S. Access Board
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.04 DC70TL-SS
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Top Landings
Curb ramps must be connected by an accessible route which, in effect, requires space at least 36 inches in length at the top of curb ramps....
-
Sections 4.2 Through 4.35 (Preamble, Section-by-Section Analysis)
• Sections 4.2 Through 4.35 Sections 4.2 through 4.35 contain the technical specifications for elements and spaces required to be accessible by the scoping provisions (sections 4.1 through...
-
11. Toilet rooms and bathing facilities
Accessible element or space ANSI A117.1 section APPLICATION 11....