Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
Types of Alternative Designs
The positioning and type of grab bars were also changed to provide more room and flexibility....
-
M302.3.2 Leg Supports (Section-by-Section Analysis)
The MDE NPRM did not propose to require stirrups to provide a method of supporting, positioning, and securing the patient’s legs for diagnostic equipment used by patients in the seated position...
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
Clear Deck Space
Clear Deck Space Clear deck space of 60 by 60 inches minimum, with a slope of not more than 1:48, must be provided at the base of a transfer wall....
-
Shower
Although not a transfer issue, lowered sidewalls were intended to facilitate assisted showering....
-
M301.3.2 Leg Supports
Where stirrups are provided, leg supports shall also be provided and shall comply with M305.4.
-
Chapter 3: Study findings
[See subsections ...]
-
1009.4.5 Grab Bars
At least one grab bar complying with 609 shall be provided on the transfer wall. Grab bars shall be perpendicular to the pool wall and shall extend the full depth of the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
11B-1009.4.5 Grab bars
At least one grab bar complying with Section 11B-609 shall be provided on the transfer wall....
-
Secondary ticket market. (Section-by-Section Analysis)
It thus encompasses a wide variety of transactions, from ticket transfers between friends to transfers using commercial exchange systems....
-
Spas
Spas Spas must provide at least one accessible means of entry, which can be a pool lift, transfer wall, or transfer system. ...
- Autoadapt Turny Evo
-
407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.