ETA Editor's Note CBC 1009.11 does not include “Directions to find other means of egress”. Therefore, the IBC requirement is more inclusive....
Search Results "Means of Egress"
-
1009.11 Instructions
-
Stair widths
Section 1009.3 states that in order to be a part of the accessible means of egress between stories, stairs shall have a clear width of 48" BETWEEN the handrails....
-
Clear Width [§405.5]
The width of ramps that are part of a means of egress may further be determined by applicable life safety codes and requirements for minimum exit widths greater than 36”....
-
1009.11 Instructions
ETA Editor's Note CBC 1009.11 does not include “Directions to find other means of egress”. Therefore, the IBC requirement is more inclusive....
-
ASME: ADA Standard Section 105.2.2
Section 105.2.2 of the ADA Standards cover references to the American Society of Mechanical Engineers (ASME) standards.
-
216 and 703 Signs
and row designations in assembly areas; occupant names, building addresses; company names and logos; signs in parking facilities (except those identifying accessible parking spaces and means...
-
Accessible Routes at Security Barriers
Section 206.8 requires that an accessible route or accessible means of egress be maintained where security barriers or check points are provided....
-
Is an accessible route required to rooftop levels?
., equipped with lighting, ventilation, and means of egress) that is “included between the upper surface of a floor and upper surface of the floor or roof next above” (§106.5)....
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
- Amramp Modular Ramps
-
Accessible Route
shall be provided in "such number, capacity, and speed" in order to provide a level of service equivalent to that provided in the same seating area to patrons who can use stairs or other means...
-
Is vertical access required to all levels of a parking garage?
., equipped with ventilation, light, and means of egress). Levels of open parking structures that do not contain occupiable space are not considered “stories” under the Standards....
-
Automatic Doors
In the final rule, this provision has been revised to also apply to automatic doors and gates not equipped with standby power that are part of an accessible means of egress....
-
11B-216.4.1 Exit doors
The exit discharge is that portion of an egress system between the termination of an exit and a public way. ◼...
-
11B-216.4.1 Exit doors
The exit discharge is that portion of an egress system between the termination of an exit and a public way. ◼...
-
Appendix C to Part 35—Guidance to Revisions to ADA Title II and Title III Regulations Revising the Meaning and Interpretation of the Definition of ‘‘Disability’’ and Other Provisions in Order To Incorporate the Requirements of the ADA Amendments Act
Add Appendix C to part 35 to read as follows: Appendix C to Part 35—Guidance to Revisions to ADA Title II and Title III Regulations Revising the Meaning and Interpretation of the...
-
11B-410.8 Restriction sign
This section includes requirements which address platform size and gate configurations for lifts with 90-degree egress, and additionally requires signs posted at the landings as follows:...
-
11B-410.8 Restriction sign
This section includes requirements which address platform size and gate configurations for lifts with 90-degree egress, and additionally requires signs posted at the landings as follows:...
-
Door and Signal Timing: ADA Standard Section 407.3.4
Section 407.3.4 covers the current ADA Standards for door and signal timing of elevator reopening devices.
-
Appendix E—Guidance to Revisions to ADA Title II and Title III Regulations Revising the Meaning and Interpretation of the Definition of ‘‘disability’’ and Other Provisions in Order To Incorporate the Requirements of the ADA Amendments Act
Add appendix E to part 36 to read as follows: Appendix E—Guidance to Revisions to ADA Title II and Title III Regulations Revising the Meaning and Interpretation of the Definition of ‘...
-
907.2.8 Group R-1
An automatic fire detection system is not required in buildings that do not have interior corridors serving guestrooms and where guestrooms have a means of egress door opening directly to...
-
Employee Work Areas [§206.2.8]
Work areas must also be served by an accessible means of egress, as required by the International Building Code. (See the ADA Scoping: New Construction Guide.)...
-
Fire Safety Evacuation Planning
It is important that evacuation chairs be located so that they do not obstruct required means of egress....
-
1132A.3 Width and height of interior doors and secondary exterior doors
The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005....