Dispensers [4.16.6] Toilet paper dispensers should be located below the side grab bar so that they do not obstruct use of this bar. For this reason, large dispensers that do not...
Search Results "Clearance in Base"
Commonly Searched Documents
-
Dispensers [4.16.6]
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide,...
-
1134A.5, Item 1
1. Floor space. There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
§ 38.159(d)(2) Location and size
(2) Location and size. The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches (760 mm) by 48 inches...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
11B-604.7.1 Dispensers
Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the...
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed. The clear floor space shall be positioned for parallel...
-
T502.2 Doorways with Lifts, Ramps or Bridgeplates
The vertical clearance at doorways with lifts, ramps or bridgeplates shall comply with T502.2....
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches....
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...
- Microsoft Word Accessibility Basics: Webinar Series Archive
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
Where bedrooms are less than 70 square feet, the section specifies that the furniture supplied with the unit cannot overlap the accessible route, maneuvering clearances required at doors...
- SafePath: Overview of Ramps and Reducers for ADA Compliance by SafePath Products
-
11B-233.3.1.2.6 Public housing facility site impracticality
The number of adaptable residential dwelling units required in non-elevator building public housing facilities shall be determined in accordance with Chapter 11A, Section 1150A.1....
-
11B-233.3.1.2.6 Public housing facility site impracticality
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect. The requirements in this section were previously found in...
-
§ 38.23(b)(13) Handrails
Handrails shall be placed to provide a minimum 11⁄2 inches knuckle clearance from the nearest adjacent surface....
-
§ 38.125(b)(13) Handrails
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
1132A.5.1 General
Section 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces. ...
-
§ 38.115(a)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
§ 38.159(b)(13) Handrails
Handrails shall be placed to provide a minimum 11/2 inches (38 mm) knuckle clearance from the nearest adjacent surface....
-
§ 38.29(b)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....