- Figure 305.5 Position of Clear Floor or Ground Space – Drawing from the U.S. Access Board
-
811.2 Clear Floor or Ground Space
811.2 Clear Floor or Ground Space. A clear floor or ground space complying with 305 shall be provided....
-
Width [4.7.3] and Surface [4.7.4]
The minimum clear width of a curb ramp is 36 inches, exclusive of flared sides....
-
1008.4.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components. Advisory 1008.4.2 Clear Floor or Ground Space....
-
1008.4.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305.2 and 305.3 shall be provided at play components. Advisory 1008.4.2 Clear Floor or Ground Space....
-
Approach
Approach Turning space (60-inch diameter or T-shaped space) for a wheelchair must be provided where the accessible route adjoins the ride, so that riders can access the ride....
-
Accessible Room Set-Up
Accessible Room Set-Up Once an accessible site is selected, it is essential that the meeting room furniture be arranged to allow everyone to fully participate. An accessible floor...
-
Accessible Routes (Exterior and Interior)
Once a voter with a disability arrives at the polling site, there must be an accessible route from the accessible parking, passenger drop-off sites, sidewalks and walkways, and...
-
403.5 Clearances
Walking surfaces shall provide clearances complying with 403.5. EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be...
-
403.5 Clearances
Walking surfaces shall provide clearances complying with 403.5. EXCEPTION: Within employee work areas, clearances on common use circulation paths shall be permitted to be...
-
Accessible Routes - Interior and Exterior
Accessible Routes - Interior and Exterior Common Problem: Both the exterior pedestrian routes (e.g., sidewalks, walkways and plazas) on a site that people use to travel from...
-
2.4 Patient Areas
Is there space in the exam room for an individual using a wheelchair or other mobility aid to move and turn around?...
-
11B-603.2 Clearances
Clearances shall comply with Section 11B-603.2.
-
Clear space
Clear space: A grid 72 inches long by 90 inches wide was used to facilitate the recording of space requirements for each WMD user (Figure 1)....
-
11B-502.2 Vehicle spaces
Car parking spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches (3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent...
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
11B-206.5.3 Transient lodging facilities
passage into and within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall comply with Section 11B-404.2.3 _|Doors, Doorways, and Gates; Clear...
-
811.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
811.2 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided....
-
4.8.2 Clear Floor or Ground Space
The clear floor or ground space around outdoor rinsing showers shall be 60 inches (1525 mm) by 60 inches (1525 mm)....
-
Clear Floor Space
Clear Floor Space The load and unload areas adjacent to ride seats designed for transfer must have a clear space of 30 by 48 inches minimum....
-
502.7 Relationship to Accessible Routes
Parking spaces and access aisles shall be designed so that cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes....
-
502.7 Relationship to Accessible Routes
Parking spaces and access aisles shall be designed so that cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes....
-
A4.22.3 Clear Floor Space
Figure 28 (section 4.16) provides minimum clear floor space dimensions for toilets in accessible “unisex” toilet rooms....