Search Results "Clear Width at Turn"
- Figure 305.3 Clear Floor or Ground Space – Drawing from the U.S. Access Board
-
Doors at Entrances to Businesses
However, some older doors are less than 36 inches wide and may not provide enough width (32 inch clear width when fully opened). Door openings can sometimes be enlarged....
-
Problem One (Voting Area)
Problem One: The voting area is in a small room and the accessible voting machine is only two feet from the check-in table. Solution: Relocate the voting area to a larger space...
-
Preferred Seat Widths
The seat width percentiles remained the same for transfers to and from the station and within each protocol....
-
Overlapping Wheelchair Turning Space
A provision in section 807.2.1 prohibiting beds from overlapping wheelchair turning space has been removed for consistency with specifications for such space in section 304, as discussed...
-
Overlapping Wheelchair Turning Space
A provision in section 806.2.6 prohibiting beds from overlapping wheelchair turning space has been removed for consistency with specifications for such space in section 304, as discussed...
-
1007.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305....
-
11B-305.1 General
Clear floor or ground space shall comply with Section 11B-305....
-
K1
K1. Is there an accessible route, at least 36 inches wide, that connects each of the shelter activity areas with the food service and eating areas (it may narrow to 32 inches wide...
-
4.10.9 Floor Plan of Elevator Cars
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car. Acceptable door opening and...
-
4.10.9 FLOOR PLAN OF ELEVATOR CARS
The floor area of elevator cars shall provide space for wheelchair users to enter the car, maneuver within reach of controls, and exit from the car. Acceptable door opening and...
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
Clear Floor or Ground Space: ADA Standard Section 707.2
A clear floor or ground space complying with 305 shall be provided....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-305.3 Size
The clear floor or ground space shall be 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
304.3.1 Circular Space
The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
Clear Floor and Turning Space Inside Examination Rooms
Clear Floor and Turning Space Inside Examination Rooms In order for accessible equipment to be usable by an individual who uses a wheelchair or other mobility device, that individual...
-
1003.2.13.7.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....