Surveying ramps, parking spaces, access aisles, door approaches and sidewalks will require you to determine if the slopes (i.e.: in the direction of travel) and cross slopes (i.e....
Search Results "Shower Slope"
Commonly Searched Documents
-
A. Measuring Slope and Cross Slope
-
Slope
Slope. The 2010 Standards provide, at section 403.3, that the cross slope of walking surfaces not be steeper than 1:48....
-
1607A.9.2 Grab bars, shower seats and accessible benches
Grab bars, shower seats and accessible benches shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab bar, shower...
-
4.3.7 Slope
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50....
-
4.3.7 SLOPE
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50....
-
11B-810.2.4 Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable....
-
Slope [§405.2] and Cross Slope [§405.3]
Slope [§405.2] and Cross Slope [§405.3] Slope represents the proportion of vertical rise to horizontal length and is specified in the Standards as a ratio (e.g., 1:12)....
-
Guestrooms with Roll-in Showers
seat in order to shower....
-
Shower Stalls [4.21]
Shower Stalls [4.21] In accessible bathing facilities, at least one tub or one shower must be accessible....
-
610.3 Shower Compartment Seats
610.3 Shower Compartment Seats....
-
4.34.5.5 SHOWERS
If a shower is provided, it shall have the following features:...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
610.3 Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
-
610.3 Shower Compartment Seats
Where a seat is provided in a standard roll-in shower compartment, it shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back...
-
11B-608 Shower compartments
[See subsections ...]
-
11B-406.2.1 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
Trail Slopes
The first general exception allows achieving trail slopes to the extent practicable if a condition for an exception prohibits full compliance with slope requirements Running slope is...
-
Running Slope [1017.7.1]
Running slope, also referred to as grade, is the lengthwise slope of a trail, parallel to the direction of travel....
-
403.3 Slope
403.3 Slope. The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48....
-
1017.7 Slopes
The slopes of trails shall comply with 1017.7....
-
1017.7 Slopes
The slopes of trails shall comply with 1017.7....
-
11B-607.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
Slope Ratio
Slope Ratio—A ratio of vertical distance to horizontal distance or rise to run....