Curbs [4.21.7] Curbs are not permitted at roll-in showers. A slope up to 2% is allowed for drainage....
Search Results "Shower Slope"
Commonly Searched Documents
-
Curbs [4.21.7]
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain....
-
11B-610.3 Shower compartment seats
In transfer-type showers, the seat shall extend from the back wall to a point within 3 inches (76 mm) of the compartment entry....
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
-
1134A.6, Item 2
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
1134A.6, Item 2
Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain....
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located on the side wall of the compartment adjacent to the 16 inches (406 mm) minimum...
-
11B-810.5.1 Slope
Rail platforms shall not exceed a slope of 1:48 in all directions....
-
11B-608.8 Shower enclosures
Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-405.3 Cross slope
Cross slope of ramp runs shall not be steeper than 1:48. Advisory 11B-405.3 Cross slope. Cross slope is the slope of the surface perpendicular to the direction of travel....
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Controls: ADA Standard Section 608.5
Section 608.5 covers the current ADA Standards for controls in shower compartments.
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Sloped Entries: ADA Standard Section 1009.3.1
Sloped entries shall comply with Chapter 4 except as modified in 1009.3.1 through 1009.3.3....
- Bon® Tool Co. Aloha Slope Checker
-
Running Slope
The slope that is parallel to the direction of travel (see cross slope)....
-
Cross Slope
The slope that is perpendicular to the direction of travel (see running slope)....
-
RUNNING SLOPE
[DSA-AC] The slope that is parallel to the direction of travel. (As differentiated from the definition of “Cross Slope”.)...
-
Slope Meters and Levels
Corada has reviewed several models of slope meters and levels to assist accessibility surveyors in measuring slope and level changes....
-
11B-405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12. Exception: Reserved....
-
CROSS SLOPE
[DSA-AC] The slope that is perpendicular to the direction of travel....
-
Seats: ADA Standard Section 608.4
Section 608.4 covers the current ADA Standards for seats in shower compartments.