Cross Slope (R302.6) (Section-by-Section Analysis) Cross slope is the slope perpendicular to the direction of pedestrian travel (see R105.5)....
Search Results "Shower Slope"
Commonly Searched Documents
-
Cross Slope (R302.6) (Section-by-Section Analysis)
-
1017.8.3 Slope
This section requires the slope of resting intervals to not be steeper than 1:48 in any direction....
-
1. Sloped Surfaces
Sloped Surfaces Measuring the slope of a ramp, parking space, walkway, or other ground or floor surface is important to identify whether the surface is accessible....
-
1017.8.3 Slope
Resting intervals shall have slopes not steeper than 1:48 in any direction....
-
1017.8.3 Slope
Resting intervals shall have slopes not steeper than 1:48 in any direction....
-
11B-608.3.2 Standard roll-in type shower compartments
[2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
4.21.6 Shower Unit
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used both as a fixed shower head and as a hand-held shower shall be provided....
-
4.21.6 SHOWER UNIT
A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
608.3.3 Alternate Roll-In Type Shower Compartments
608.3.3 Alternate Roll-In Type Shower Compartments....
-
405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
405.2 Slope
405.2 Slope. Ramp runs shall have a running slope not steeper than 1:12....
-
405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12....
-
2. Roll-in Shower Size
If there are more than 50 guestrooms/suites, are all required roll-in showers at least 30" wide by 60" long or 36" wide by 60", as configured in Figure 57 below, so persons who use wheelchairs...
-
Light Rail Platform Slope
The Board has explicitly specified that rail platforms shall slope no more than 1:48 in any direction, consistent with cross slope provisions for walking surfaces in section 403....
-
2010 ADA Standards - Plan Review Tool - Slopes
2010 ADA Standards - Plan Review Tool - Slopes Click here to view/download the pdf "2010 ADA Standards - Plan Review Tool - Slopes" (774 KB) * * * * * * *...
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
Running Slope
Running Slope - The slope that is parallel to the direction of travel (see cross slope)....
-
Cross Slope
Cross Slope - The slope that is perpendicular to the direction of travel (see running slope)....
-
11B-608.1 General
Shower compartments shall comply with Section 11B-608. Advisory 11B-608.1 General....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-403.3 Slope
The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48....
-
11B-403.3 Slope
The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48....
-
Slope: ADA Standard Section 405.7.1
Section 405.7.1 covers the current ADA Standards for the slope in ramp landings.