Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. ...
Search Results "Patient in Seated Position"
Commonly Searched Documents
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
-
M304 Diagnostic Equipment Used by Patients in Standing Position (Section-by-Section Analysis)
M304 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a standing position such as a weight scale or x-ray equipment that is used in a standing...
-
D. M304 Diagnostic Equipment Used by Patients in a Standing Position
M304 provides the technical requirements for diagnostic equipment used by patients in a standing position....
-
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
Generally, for positioning supports, the table is supporting the full weight of the patient rather than the support....
-
4.1.1 Range of Examination Table and Chair Configurations
Equipment designed for patients seated or in semi-supine positions (M302) Examination chairs Dental chairs Optometric chairs Otolaryngology (ENT) chairs...
-
5.4.3 Transfer Support Height for M301 and M302
The purpose of a minimum height is to ensure that the gripping surface is at an adequate height to facilitate positioning during a transfer....
-
M305.2 Transfer Supports
M305.2 Transfer Supports M305.2.2 Transfer Supports Structural Strength Proposed requirement: Transfer supports and their connections shall be capable of resisting vertical...
-
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.9 Interruptions Along Transfer Support Gripping for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
patients lie in a supine, prone, or side-lying position (see Figure 5.4.2.2)....
-
Car Position Indicators: ADA Standard Section 407.4.8
Section 407.4.8 covers the current ADA Standards for elevator car position indicators.
-
M302.3.1 Transfer Supports (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that transfer supports must be provided for use with transfer sides on diagnostic equipment used by patients in the seated position, and that these...
-
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.6 Transfer Support Gripping Surface Cross Section for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.7 Transfer Support Gripping Surface Clearance for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
5.2.2.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
5.2.2.1 Transfer Surface Width
The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....
-
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.4 Transfer Support Distance From Transfer Surface for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position....
-
19 Inch Low Height
, shower seats, dressing benches).”7 In addition, the Access Board recommended, “Where patient support surfaces are contoured or upholstered for patient comfort or to support patient positioning...
-
How to Measure Transfer Surface Height
Manufacturers designed the shape of the seat for these tables to meet both patient accessibility and clinical needs, resulting in a complex, contoured shape....
-
5.2.2.1 Transfer Surface Width Recommendations for M302
Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily used by patients...
-
M302.3.2 Leg Supports (Section-by-Section Analysis)
The MDE NPRM did not propose to require stirrups to provide a method of supporting, positioning, and securing the patient’s legs for diagnostic equipment used by patients in the seated position...
-
M302.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used by patients in the seated position of 21 inches wide and 15 inches deep (proposed M302.2.2)....
-
5.6.1 Stirrups Provision for M301
The proposed provision ensures a method of supporting, positioning, and securing the patient’s legs. NPRM Proposed Provision: M301.3.2 Stirrups....
-
M304.1 General
Diagnostic equipment used by patients in a standing position shall comply with M304....