Section 408.3 covers the current ADA Standards for limited-use/limited-application elevator doors.
Search Results "Magnetic Door Holder"
Commonly Searched Documents
-
Elevator Doors: ADA Standard Section 408.3
-
Sliding Doors: ADA Standard Section 408.3.1
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator sliding doors.
-
Swinging Doors: ADA Standard Section 408.3.2
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator swinging doors.
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
Controls: ADA Standard Section 404.3.5
Section 404.3.5 covers the current ADA Standards for controls at automatic and power-assisted doors and gates.
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
Automatic and Power-Assisted Doors and Gates: ADA Standard Section 404.3
Section 404.3 covers the current ADA Standards for automatic and power-assisted doors and gates.
-
11B-408.3 Elevator doors
Elevator hoistway doors shall comply with Section 11B-408.3....
-
Closing Speed: ADA Standard Section 404.2.8
Section 404.2.8 covers the current ADA Standards for the closing speed of doors.
-
11B-408.3.1 Sliding doors
Sliding hoistway and car doors shall comply with Sections 11B-407.3.1 through 11B-407.3.3 and 11B-408.4.1....
-
11B-404.2.8 Closing speed
Door and gate closing speed shall comply with Section 11B-404.2.8....
-
11B-408.3.2 Swinging doors
Swinging hoistway doors shall open and close automatically and shall comply with Sections 11B-404, 11B-407.3.2 and 11B-408.3.2....
-
11B-407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
11B-404.1 General
Doors, doorways, and gates that are part of an accessible route shall comply with Section 11B-404....
-
Are screen doors or storm doors considered “doors in series”?
No, screen or storm doors are not considered “doors in series” since they are part of the same doorway opening as the entry door....
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-407.3.6 Width
The width of elevator doors shall comply with Table 11B-407.4.1. Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall be permitted....
-
4.13.11* DOOR OPENING FORCE
The maximum force for pushing or pulling open a door shall be as follows: (1) Fire doors shall have the minimum opening force allowable by the appropriate administrative authority....
-
A4.13.11 Door Opening Force
Although some people cannot manage the allowable forces in this guideline and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...
-
A4.13.11 DOOR OPENING FORCE
Although some people cannot manage the allowable force in this standard and many others have difficulty, door closers must have certain minimum closing forces to close doors satisfactorily...