Surfaces of transfer walls shall not be sharp and shall have rounded edges....
Search Results "Barrier Wall"
-
11B-1009.4.4 Surface
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
Height
Height The transfer wall height must be 16 inches minimum to 19 inches maximum, measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
Controls: ADA Standard Section 607.5
Section 607.5 covers the current ADA Standards bathtub controls.
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
11B-607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....
-
III-4.4200 Readily achievable barrier removal
III−4.4200 Readily achievable barrier removal. Public accommodations are required to remove barriers only when it is "readily achievable" to do so....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Section 36.304 Removal of Barriers (Preamble, Section-by-Section Analysis)
Section 36.304 Removal of Barriers Section 36.304 requires the removal of architectural barriers and communication barriers that are structural in nature in existing facilities, where...
-
Section 36.304 Removal of Barriers (Section-By-Section Analysis and Response to Comments)
Section 36.304 Removal of Barriers (Section-By-Section Analysis and Response to Comments) Section 36.304 requires the removal of architectural barriers and communication barriers that...
-
Security Barriers [§206.8]
Security Barriers [§206.8] Security bollards and screening devices at accessible entrances cannot obstruct accessible routes or accessible means of egress....
-
Side Wall: ADA Standard Section 604.5.1
Section 604.5.1 covers the current ADA Standards for side wall grab bars that are used for water closets.
-
Architectural Barriers
Architectural Barriers....
-
Examples of Barrier Removal
Examples of Barrier Removal The following examples illustrate common barriers and suggest solutions that may be readily achievable....
-
III-4.4000 Removal of barriers
[See subsections ...]
-
§ 36.304 Removal of barriers.
[Order No. 1513-91, 56 FR 35592, July 26, 1991, as amended by AG Order No. 3181-2010, 75 FR 56254, Sept. 15, 2010; AG Order No. 3332-2012, 77 FR 30179, May 21, 2012]