Where gates or barriers are constructed to control access to trails, gates and barriers shall comply with 7.4.12....
Search Results "Barrier Wall"
-
7.4.12 Gates and Barriers
-
Gates and Barriers on Trails
If gates or barriers are constructed to control access to trails, include openings wide enough to allow hiker passage....
-
Back Wall: ADA Standard Section 607.4.1.1
Section 607.4.1.1 covers the current ADA Standards for back wall grab bars in bathtubs with permanent seats.
-
Back Wall: ADA Standard Section 607.4.2.1
Section 607.4.2.1 covers the current ADA Standards for back wall grab bars in bathtubs without permanent seats.
-
Head End Wall: ADA Standard Section 607.4.2.3
Section 607.4.2.3 covers the current ADA Standards for grab bars on the head end wall of bathtubs without permanent seats.
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
Transfer Walls: ADA Standard Section 1009.4
Transfer walls shall comply with 1009.4....
-
11B-1009.4 Transfer walls
Transfer walls shall comply with Section 11B-1009.4....
-
11B-1009.4 Transfer walls
Transfer walls shall comply with Section 11B-1009.4....
-
Control End Wall: ADA Standard Section 607.4.2.2
Section 607.4.2.2 covers the current ADA Standards for grab bars on the control end of bathtubs without permanent seats.
-
Control End Wall: ADA Standard Section 607.4.1.2
Section 607.4.1.2 covers the current ADA Standards for grab bars on the control end of bathtubs with permanent seats.
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
Surface: ADA Standard Section 1009.4.4
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
11B-1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
Height: ADA Standard Section 1009.4.2
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
Foot Travel on Trails and Roads With Restrictions
When gates, barriers, or berms are installed on a trail or a road to close it to motorized traffic or for other purposes, but foot travel is encouraged beyond the closure, people who use...
-
1009.4 Transfer Walls
1009.4 Transfer Walls. Transfer walls shall comply with 1009.4....
-
1009.4 Transfer Walls
Transfer walls shall comply with 1009.4....
-
1009.4 Transfer Walls
Transfer walls shall comply with 1009.4....
-
11B-1009.4 Transfer walls
Transfer walls shall comply with Section 11B-1009.4....