A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
Search Results "Transfer Support"
-
11B-1009.4.1 Clear deck space
-
608.7 Thresholds
In transfer type shower compartments, thresholds ½ inch (13 mm) high maximum shall be beveled, rounded, or vertical....
-
608.7 Thresholds
In transfer type shower compartments, thresholds 1/2 inch (13 mm) high maximum shall be beveled, rounded, or vertical....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Secondary ticket market. (Section-by-Section Analysis)
It thus encompasses a wide variety of transactions, from ticket transfers between friends to transfers using commercial exchange systems....
-
M302.2.3 Size (Section-by-Section Analysis)
The Access Board also solicited comment in question 16 on whether the transfer surface size proposed for seated position diagnostic equipment was sufficient to facilitate independent transfer...
-
M302.2 Transfer Surface (Section-by-Section Analysis)
This is an introductory section.
-
QUESTION: SHOULD PVOs MODIFY POLICIES TO ACCOMMODATE REQUESTS BY PEOPLE WITH DISABILITIES TO TRAVEL WITH ANIMALS THAT DO NOT MEET THE DEFINITION OF SERVICE ANIMALS?
In the case of someone requesting the accommodation of an emotional support animal, this could include obtaining recent current documentation (i.e., no older than one year from the date...
-
5.6.1 Stirrups Provision for M301
ANSI/AAMI HE75 recommends “[f]or patients with limited leg strength and control, instead of stirrups that support only the foot and require active user leg strength, leg supports that support...
-
Participants
Further demographic details of the study can be seen in Table 3, including hours using a wheelchair per day, years using a wheelchair, number of level and non-level transfers and average...
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
When patients transfer on the long side, table depth may be equal to the transfer surface depth....
-
Service Animals
Under the ADA, “comfort,” “therapy,” or “emotional support” animals do not meet the definition of a service animal....
-
A4.17.3 Size and Arrangement
A standard stall provides a clear space on one side of the water closet to enable persons who use wheelchairs to perform a side or diagonal transfer from the wheelchair to the water closet...
-
Clear Floor or Ground Space: ADA Standard Section 1002.6.1
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
11B-1002.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided in the load and unload area adjacent to the transfer device....
-
Floor Height [1013.4]
This height allows people using mobility devices to transfer from the device to the platform surface....
-
M301.3.2 Leg Supports (Section-by-Section Analysis)
In the final rule the Access Board has decided to move the technical requirements for stirrups to M305, which includes all of the technical requirements for supports....
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
-
M305.4 Leg Supports (Section-by-Section Analysis)
M301 and M302 have been relocated to M305 Supports....
-
Medical Diagnostic Equipment Advisory Committee
Medical Diagnostic Equipment Advisory Committee MEDICAL DIAGNOSTIC EQUIPMENT ADVISORY COMMITTEE - Minority Report Regarding: 17 Inch Low Transfer Surface Height 09.27.13 These...
-
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301)
5.2.1.3 Transfer Surface Size Recommendations for Stretchers (M301) The Committee recommends a minimum transfer surface size of 28 inches wide by 17 inches deep for stretchers located...
-
11B-1008.4.2 Clear floor or ground space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
11B-1008.4.2 Clear floor or ground space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....